A19620 C
125
Trouble shooting
4.5
Summary table of faults and alarms
Number
Alarm or
Fault
Fault displayed
01 to 03
F
Data memories
04 to 08
F
Data memories
46 - 47
F
Data memories
13 - 17 - 19
F
Data memories
22 - 26
F
Data memories
30 - 31
F
Data memories
09 and 11
A
Time out
10
A
V24 Time out
14
F
V24 Data
15
F
Data
18
F
Algo number not found
21
A
Doubled printing
27
A
Printing library size
28
A
Extension cassette disconnection
32
F
Auto-dating
33
A
Software versions
37
F
Reading/writing industrial interface eeprom
38 - 39
A
Reading/writing control and ink module eeprom
40
A
Conveyor speed
44
A
Corrupted data in extension cassette library
45
A
Function not available
48
F
Algo not available
49
F
Character generator
50 - 52
A/F
Ink level
51 - 53
A/F
Additive level
54
F
Cartridge full on draining
60
A
Ink Elv(u:0)
61
A
Additive Elv(u:1)
62
F
Buffer Elv (u:2)
63
F
Accumulator Elv (u:3)
64
A
Condensor Elv (u:4)
70
A
Concentration high
71
F
Pressure sensor unit.
72
F
Stalling motor
73
F
Ink transfert time out
74
A
Air inflating time out
75
A
Air pocket
76
A
Jet purge time out
77
A
Compression rate
78
F
Machine empty
79
F
Condenser overflow
81 - 82
F
Drop detection (jet 1-2)
83
F
Concentration out of range
84
F
Open cover
85
F
Vacuum fault
86 - 87
F
EHT fault
88
F
Ink module
90
A
Temperature fault
92
F
Pressure servo.
93
F
Gutter closed
Содержание Imaje S7 Mega
Страница 1: ......
Страница 18: ...16 A19620 C Introduction to the printer NOTES ...
Страница 116: ...114 A19620 C Routine maintenance NOTES ...
Страница 137: ...A19620 C 135 TECHNICAL SPECIFICATIONS 8 ...
Страница 142: ...140 A19620 C Technical specifications NOTES ...
Страница 154: ...152 A19620 C 09 2002 ...