![Dover Imaje S7 Mega Скачать руководство пользователя страница 121](http://html1.mh-extra.com/html/dover/imaje-s7-mega/imaje-s7-mega_manual_2524825121.webp)
A19620 C
119
Trouble shooting
3.2
Using the Terminal
In the STATUS sub-menu under the PRODUCTION menu, a dialog box tells you the status of
the machine and of its operating parameters:
This function provides a real-time indication of the status of the machine and of its operating
parameters:
• Ink M. status:
Shows whether the ink circuit is in service or not.
• Jet status:
Shows whether the jet is in service and ready to print or otherwise.
• Ref P:
Shows the ink circuit set-point pressure.
• Acc P:
Shows actual ink circuit pressure.
• Tamp P:
Shows the negative pressure value at the gutter.
• T°C:
Shows the printer operating temperature.
• Jet speed 1:
Shows the speed of the jet (with a twin-jet machine the speed parameter shown is for jet no 2).
• Display/acknowledgement of Faults and Alarms:
When Faults or Alarms occur, they are displayed in clear text in a dialog box.
The figure at the top right indicates the number of faults.
A recommendation is displayed as to how to correct the fault
To acknowledge, press
h
.
S7
PRODUCTION
↑ ↓
: for selection and VALID
Printer
Message
Status
mAint
.
Ink M.status: Ready
Jet status: Ready
Ref P: + 2.39 Acc P: + 2.43 Tamp P: -0.09
T°C : 20
Jet speed 1: 20.00 m/s
85 Default
01/01
Jet vacuum
Restart jet, check gutter function
↑ ↓
: list, VALID : acknowledge
Содержание Imaje S7 Mega
Страница 1: ......
Страница 18: ...16 A19620 C Introduction to the printer NOTES ...
Страница 116: ...114 A19620 C Routine maintenance NOTES ...
Страница 137: ...A19620 C 135 TECHNICAL SPECIFICATIONS 8 ...
Страница 142: ...140 A19620 C Technical specifications NOTES ...
Страница 154: ...152 A19620 C 09 2002 ...