valve opening start pressure. In a period of 60 seconds, it
is acceptable to have a pressure of 0.2 bar higher when
the valve passes the complete flow rate.
The value above apply to all package configurations
having the same pulley ration and compressor.
1.3.4 Acceptable oil pressure range
The oil pressure is measured at the tap point located on the
synchromesh gear box (item G on the outline dra-wings) :
In normal operation, the compressor, the silencer, the
outlet piping and their surrounding parts (covers…) may
reach high temperatures (up to 200°C). Make sure that
you do not put sensitive components close to a heat
source, and affix plates warning users that the compres-
sor is hot, to avoid any burn hazards.
Having the compressor run above its maximal temperatu-
re may lead to serious body injuries or property damages.
1.4 Outlines drawings
The overall dimensions of the different packages are
given on the table below :
TYPHON 1000 IC
The above dimensions are given with the shaft axis
mounted in the closest position to the chair.3 hole loca-
tions exist on the chair :
1
st
hole
3
rd
hole
2
nd
hole
Pulley
ratio
X
Y
D
1:1
185
524
231
1:1,12
172
503
257
1:1,25
173
503
287
RIGTH
DRIVEN
PTO
1:1,4
170
506,5
322
1:1
134
519
231
1:1,12
188,5
499
257
1:1,25
119
498
287
LEFT
DRIVEN
PTO
1:1,4
116
502,5
322
Pulley
ratio
Pulley
dia.
Pulley
dia.
Belt
lenght
Tension
setting with
66N
1:1
224
224
1400
6,4
1:1,12
224
250
1500
6
1:1,25
224
280
1550
6
1:1,4
224
315
1600
6
D
X + 10
Y
+
10
Length
Width
Height
TYPHON
1000 IC
Width
870
Length to truck frame
775
Overall length
1034
Height
650
Pressure (bar)
TYPHON Packages
Mini
0.2
Maxi
2.3
6/21
NT 1401-F00 12.05 Cold front outlet Intercooler TYPHON e
11.. G
GE
EN
NE
ER
RA
ALL D
DA
AT
TA
A ((ccoonnttiinnuuoouuss))