EDITING SHOW PARAMETERS

 

A number of parameters can be edited in recorded shows and for system-wide functions. These include
the start point, end point, looping/linking status, linked show number, cross fading, recording lockout, end
of show output disable, and front panel lockout.

Setting start and end points

The [REWIND] and [FORWARD] buttons are used to set the start and end points. These buttons are only
active while a show is paused. When paused, the buttons can be used to move the playback pointer
forward or backward through the show. The longer each button is held, the faster the show will be
forwarded or rewound. When the playback pointer is at the top of the recorded show, the START LED will
flash. When the playback pointer reaches the bottom of the recorded show, the END LED will flash. When
the playback pointer is at the START POINT, the START LED will turn on solid. When the playback pointer
is at the end point, the END LED will turn on solid. See below for the meanings of these terms and for
details on editing them.

Start point

The START POINT is the point in the show at which playback will begin when that show is selected. To
set the START POINT, do the following:
1.

Start playing the show to be edited.

2.

Pause the show near the desired START POINT.

3.

While paused, use the [REWIND] or [FORWARD] buttons to move the playback pointer and locate
the desired START POINT.

4.

Press and hold the [RECORD] button. While holding the [RECORD] button, press the [REWIND]
button. After it is pressed, the START LED will turn on indicating that this point in the show is the
start.

Note: 

!

The START POINT is set to the top of the show when that show is first recorded.

!

The START POINT must be set to a point in the show before the END POINT. If you attempt to set the START POINT
to a point after the END POINT, the set START POINT command will be ignored.

!

Once recorded, show data is never discarded. If you set a START POINT a few minutes into a recorded show, those
minutes of data still exist. You can start the show, pause it, and rewind into the previously trimmed out area. A new
START POINT can then be set.

End point

The END POINT is the end of the show. To set the END POINT, do the following:
1.

Start playing the show to be edited.

2.

Pause the show near the desired END POINT.

3.

While paused, use the [REWIND] or [FORWARD] button to move the playback pointer and locate
the desired END POINT.

4.

Press and hold the [RECORD] button. While holding the [RECORD] button, press the [FORWARD]
button. After it is pressed, the END LED will turn on indicating that this point in the show is the END
POINT.

Note: 

!

The END POINT is set to the bottom of the show when that show is first recorded.

!

The END POINT must be set to a point in the show after the START POINT. If you attempt to set the END POINT  to
a point before the START POINT, the set END POINT command will be ignored.

!

Once recorded, show data is never discarded.  If you set an END POINT a few minutes before the bottom of a recorded
show, those minutes of data still exist. You can start the show, pause it, and forward into the previously trimmed out
area. A new END POINT can then be set.

Содержание RERUN Series

Страница 1: ...RERUN RACKMOUNT DMX512 RECORDER MODEL RERUN R1 RERUN R2 RERUN R3 RERUN R4 OWNERS MANUAL Doug Fleenor Design 396 Corbett Canyon Road Arroyo Grande CA 93420 805 481 9599 Manual Revision July 2020 ...

Страница 2: ...via a 3 pin XLR connector on the rear of the chassis in order to support additional universes The Rerun Rackmount occupies 1U of rackspace and comes standard with rack ears for easy installation Also included is a clear security panel designed to block unintended button presses Preset 10 remote stations can be added to remotely select shows Power to the Rerun Rackmount is provided by the attached ...

Страница 3: ...d 3 pin female Neutrik D 1 Series XLR connector or optional terminal block I C Inter Integrated Circuit Bus 2 Indicators Ten green SHOW LEDs One green PAUSE LED One green LOOP LED One yellow START LED One yellow END LED Up to four red INPUT RECORD LEDs One per universe User controls Ten SHOW buttons One PAUSE button One LOOP button One REWIND button One FORWARD button One RECORD button Power input...

Страница 4: ... Figure 1 Multiple remote panels can be connected in a daisy chain manner to the DMX512 input on the Rerun Rackmount NOTE Remote panels must be wired to the DMX512 Universe 1 INPUT connector on the Rerun The remote panel must be configured as a remote station Remove the jumpers located at JP2 and JP4 to configure a Preset 10 Architectural as a remote station Figure 2 Place the jumper over only one...

Страница 5: ...NK OFF SHOW AT END POINT AND LOOPED TO START POINT OFF OFF OFF OFF OFF ON RECEIVING DMX512 THE RERUN IS LOCKED OUT FROM RUNNING SHOW S AND IS PASSING CONSOLE DATA TO THE OUTPUT ALL FLASH OFF OFF OFF OFF ON RECEIVING DMX512 READY TO RECORD ON OFF OFF OFF OFF FLASH SHOW CURRENTLY BEING RECORDED ON ON OFF ON N A N A OFF LOOP STATUS IN SHOW RECORD ON ENABLED OFF DISABLED ON FLASH ON N A N A N A OFF ON...

Страница 6: ... show with no DMX present on universes other than 1 causes DMX values of 0 to be recorded in those universes This applies to universes 2 4 only It is recommended that your console output all 512 slots When fewer than 512 slots are received a level of 0 will be stored for all slots above those received To allow you to observe the show being recorded the Rerun Rackmount echos data being received on ...

Страница 7: ...meters can be edited See the section on show editing for details A paused show can be resumed by pressing the PAUSE button again The PAUSE LED will extinguish and the show will continue playing from the point at which it was paused Looping a show When a show is selected its recorded loop status is loaded This is indicated by the LOOP LED The loop status of a show can be temporarily overridden Whil...

Страница 8: ...ress the REWIND button After it is pressed the START LED will turn on indicating that this point in the show is the start Note The START POINT is set to the top of the show when that show is first recorded The START POINT must be set to a point in the show before the END POINT If you attempt to set the START POINT to a point after the END POINT the set START POINT command will be ignored Once reco...

Страница 9: ...g selections made previously Linking This feature is for advanced users only Linking is similar to show looping However with linking when a show reaches its end instead of looping to re start itself a different show is started You can select which show is linked This powerful feature allows the user to create longer and more complex shows To link shows do the following 1 Start playing the first sh...

Страница 10: ...ue to send their last values during the fade and then they will run properly as the show begins running With the crossfade attribute disabled all universes will start running at the same time End of show output When a show is set to stop running at the END POINT not looping the behavior of the Rerun Rackmount can be set up in two different ways By default a show stops at its END POINT and the Reru...

Страница 11: ...tate By default the software record lockout feature is disabled recording enabled Front panel lockout The front panel buttons on the Rerun Rackmount can be locked to prevent tampering with a running show The ability to lock out the front panel is disabled by default To enable or disable the ability to lock the front panel do the following 1 Start playing any show 2 Pause the show at any point 3 Pr...

Страница 12: ...fault When enabled the grand master feature does not alter the levels of the incoming DMX512 levels LIMITED MANUFACTURER S WARRANTY Products manufactured by Doug Fleenor Design DFD carry a five year parts and labor warranty against manufacturing defects It is the customer s responsibility to return the product to DFD at the customer s expense If covered under warranty DFD will repair the unit and ...