EDITING SHOW PARAMETERS 

(CONTINUED)

Grand master

A grand master feature is available as a factory option. This feature allows the user to alter the overall level
output of the current show. The REWIND and FORWARD buttons are used to access this feature while
the show is running. The REWIND button raises the grand master and the FORWARD button lowers it.

The grand master feature (if enabled) only operates on universe 1. There is no facility for other universes
to process the grand master feature at this time. It is recommended that the grand master feature should
not be used in multi-universe Rerun DMX recorders. 

Note: 

!

The grand master feature can only be enabled at the factory. It cannot be enabled in the field.

!

The grand master feature is disabled by default.

!

When enabled, the grand master feature does not alter the levels of the incoming DMX512 levels.

LIMITED MANUFACTURER’S WARRANTY

Products manufactured by Doug Fleenor Design (DFD) carry a five-year parts and labor warranty against
manufacturing defects. It is the customer's responsibility to return the product to DFD at the customer's
expense. If covered under warranty, DFD will repair the unit and pay for return ground shipping. If a trip
is necessary to the customer's site to solve a problem, the expenses of the trip must be paid by the
customer.

This warranty covers manufacturing defects. It does not cover damage due to abuse, misuse, negligence,
accident, alteration, or repair by other than by Doug Fleenor Design.

Most non-warranty repairs are made for a fixed $50.00 fee, plus shipping.

Doug Fleenor Design, Inc.

396 Corbett Canyon Road
Arroyo Grande, CA 93420
(805) 481-9599 voice and FAX
(888) 4-DMX512  toll free (888) 436-9512
web site: http://www.dfd.com
e-m ail: info@ dfd.com

Содержание RERUN Series

Страница 1: ...RERUN RACKMOUNT DMX512 RECORDER MODEL RERUN R1 RERUN R2 RERUN R3 RERUN R4 OWNERS MANUAL Doug Fleenor Design 396 Corbett Canyon Road Arroyo Grande CA 93420 805 481 9599 Manual Revision July 2020 ...

Страница 2: ...via a 3 pin XLR connector on the rear of the chassis in order to support additional universes The Rerun Rackmount occupies 1U of rackspace and comes standard with rack ears for easy installation Also included is a clear security panel designed to block unintended button presses Preset 10 remote stations can be added to remotely select shows Power to the Rerun Rackmount is provided by the attached ...

Страница 3: ...d 3 pin female Neutrik D 1 Series XLR connector or optional terminal block I C Inter Integrated Circuit Bus 2 Indicators Ten green SHOW LEDs One green PAUSE LED One green LOOP LED One yellow START LED One yellow END LED Up to four red INPUT RECORD LEDs One per universe User controls Ten SHOW buttons One PAUSE button One LOOP button One REWIND button One FORWARD button One RECORD button Power input...

Страница 4: ... Figure 1 Multiple remote panels can be connected in a daisy chain manner to the DMX512 input on the Rerun Rackmount NOTE Remote panels must be wired to the DMX512 Universe 1 INPUT connector on the Rerun The remote panel must be configured as a remote station Remove the jumpers located at JP2 and JP4 to configure a Preset 10 Architectural as a remote station Figure 2 Place the jumper over only one...

Страница 5: ...NK OFF SHOW AT END POINT AND LOOPED TO START POINT OFF OFF OFF OFF OFF ON RECEIVING DMX512 THE RERUN IS LOCKED OUT FROM RUNNING SHOW S AND IS PASSING CONSOLE DATA TO THE OUTPUT ALL FLASH OFF OFF OFF OFF ON RECEIVING DMX512 READY TO RECORD ON OFF OFF OFF OFF FLASH SHOW CURRENTLY BEING RECORDED ON ON OFF ON N A N A OFF LOOP STATUS IN SHOW RECORD ON ENABLED OFF DISABLED ON FLASH ON N A N A N A OFF ON...

Страница 6: ... show with no DMX present on universes other than 1 causes DMX values of 0 to be recorded in those universes This applies to universes 2 4 only It is recommended that your console output all 512 slots When fewer than 512 slots are received a level of 0 will be stored for all slots above those received To allow you to observe the show being recorded the Rerun Rackmount echos data being received on ...

Страница 7: ...meters can be edited See the section on show editing for details A paused show can be resumed by pressing the PAUSE button again The PAUSE LED will extinguish and the show will continue playing from the point at which it was paused Looping a show When a show is selected its recorded loop status is loaded This is indicated by the LOOP LED The loop status of a show can be temporarily overridden Whil...

Страница 8: ...ress the REWIND button After it is pressed the START LED will turn on indicating that this point in the show is the start Note The START POINT is set to the top of the show when that show is first recorded The START POINT must be set to a point in the show before the END POINT If you attempt to set the START POINT to a point after the END POINT the set START POINT command will be ignored Once reco...

Страница 9: ...g selections made previously Linking This feature is for advanced users only Linking is similar to show looping However with linking when a show reaches its end instead of looping to re start itself a different show is started You can select which show is linked This powerful feature allows the user to create longer and more complex shows To link shows do the following 1 Start playing the first sh...

Страница 10: ...ue to send their last values during the fade and then they will run properly as the show begins running With the crossfade attribute disabled all universes will start running at the same time End of show output When a show is set to stop running at the END POINT not looping the behavior of the Rerun Rackmount can be set up in two different ways By default a show stops at its END POINT and the Reru...

Страница 11: ...tate By default the software record lockout feature is disabled recording enabled Front panel lockout The front panel buttons on the Rerun Rackmount can be locked to prevent tampering with a running show The ability to lock out the front panel is disabled by default To enable or disable the ability to lock the front panel do the following 1 Start playing any show 2 Pause the show at any point 3 Pr...

Страница 12: ...fault When enabled the grand master feature does not alter the levels of the incoming DMX512 levels LIMITED MANUFACTURER S WARRANTY Products manufactured by Doug Fleenor Design DFD carry a five year parts and labor warranty against manufacturing defects It is the customer s responsibility to return the product to DFD at the customer s expense If covered under warranty DFD will repair the unit and ...

Отзывы: