PRODUCT DESCRIPTION

The 

Rerun Rackmount 

is a lighting control station capable of storing up to ten 40-minute shows on up to

4 universes. Shows are recorded by capturing the output of a DMX512 console. The recorded show start
and end points may be trimmed non-destructively. Each show can be set to hold the last look, loop to itself
or link to another show. Shows are started by pressing one of the ten show buttons.

The 

Rerun Rackmount

 can be built to support multiple universes of DMX512. As many as four universes

can be supported in a single 1U chassis. The 

Rerun-R1

 supports 1 universe of DMX512, the 

Rerun-R2

supports 2 universes of DMX512, the 

Rerun-R3

 supports 3 universes of DMX512, and the 

Rerun-R4

supports 4 universes of DMX512. Expansion units may be added via a 3-pin XLR connector on the rear
of the chassis in order to support additional universes.

The

 Rerun Rackmount 

occupies 1U of rackspace, and comes standard with rack ears for easy installation.

Also included is a clear security panel designed to block unintended button presses. 

Preset 10 

remote

stations can be added to remotely select shows

Power to the 

Rerun Rackmount 

is provided by the

attached wall power supply.

The 

Rerun Rackmount 

system can work in conjunction with a lighting console, automatically switching

between recorded shows and console control. When the console generates DMX512, the 

Rerun

Rackmount 

retransmits the incoming DMX512 data. Thus the console operates normally. Upon loss of

DMX512 from the console, the 

Rerun Rackmount

 starts its previously active show.

Rerun 

also is available in an architectural version (model RERUN-A) and a portable version (model

RERUN-P). The 

Rerun Architectural 

and 

Rerun Portable 

units can each support one universe of DMX512

data.

Содержание RERUN Series

Страница 1: ...RERUN RACKMOUNT DMX512 RECORDER MODEL RERUN R1 RERUN R2 RERUN R3 RERUN R4 OWNERS MANUAL Doug Fleenor Design 396 Corbett Canyon Road Arroyo Grande CA 93420 805 481 9599 Manual Revision July 2020 ...

Страница 2: ...via a 3 pin XLR connector on the rear of the chassis in order to support additional universes The Rerun Rackmount occupies 1U of rackspace and comes standard with rack ears for easy installation Also included is a clear security panel designed to block unintended button presses Preset 10 remote stations can be added to remotely select shows Power to the Rerun Rackmount is provided by the attached ...

Страница 3: ...d 3 pin female Neutrik D 1 Series XLR connector or optional terminal block I C Inter Integrated Circuit Bus 2 Indicators Ten green SHOW LEDs One green PAUSE LED One green LOOP LED One yellow START LED One yellow END LED Up to four red INPUT RECORD LEDs One per universe User controls Ten SHOW buttons One PAUSE button One LOOP button One REWIND button One FORWARD button One RECORD button Power input...

Страница 4: ... Figure 1 Multiple remote panels can be connected in a daisy chain manner to the DMX512 input on the Rerun Rackmount NOTE Remote panels must be wired to the DMX512 Universe 1 INPUT connector on the Rerun The remote panel must be configured as a remote station Remove the jumpers located at JP2 and JP4 to configure a Preset 10 Architectural as a remote station Figure 2 Place the jumper over only one...

Страница 5: ...NK OFF SHOW AT END POINT AND LOOPED TO START POINT OFF OFF OFF OFF OFF ON RECEIVING DMX512 THE RERUN IS LOCKED OUT FROM RUNNING SHOW S AND IS PASSING CONSOLE DATA TO THE OUTPUT ALL FLASH OFF OFF OFF OFF ON RECEIVING DMX512 READY TO RECORD ON OFF OFF OFF OFF FLASH SHOW CURRENTLY BEING RECORDED ON ON OFF ON N A N A OFF LOOP STATUS IN SHOW RECORD ON ENABLED OFF DISABLED ON FLASH ON N A N A N A OFF ON...

Страница 6: ... show with no DMX present on universes other than 1 causes DMX values of 0 to be recorded in those universes This applies to universes 2 4 only It is recommended that your console output all 512 slots When fewer than 512 slots are received a level of 0 will be stored for all slots above those received To allow you to observe the show being recorded the Rerun Rackmount echos data being received on ...

Страница 7: ...meters can be edited See the section on show editing for details A paused show can be resumed by pressing the PAUSE button again The PAUSE LED will extinguish and the show will continue playing from the point at which it was paused Looping a show When a show is selected its recorded loop status is loaded This is indicated by the LOOP LED The loop status of a show can be temporarily overridden Whil...

Страница 8: ...ress the REWIND button After it is pressed the START LED will turn on indicating that this point in the show is the start Note The START POINT is set to the top of the show when that show is first recorded The START POINT must be set to a point in the show before the END POINT If you attempt to set the START POINT to a point after the END POINT the set START POINT command will be ignored Once reco...

Страница 9: ...g selections made previously Linking This feature is for advanced users only Linking is similar to show looping However with linking when a show reaches its end instead of looping to re start itself a different show is started You can select which show is linked This powerful feature allows the user to create longer and more complex shows To link shows do the following 1 Start playing the first sh...

Страница 10: ...ue to send their last values during the fade and then they will run properly as the show begins running With the crossfade attribute disabled all universes will start running at the same time End of show output When a show is set to stop running at the END POINT not looping the behavior of the Rerun Rackmount can be set up in two different ways By default a show stops at its END POINT and the Reru...

Страница 11: ...tate By default the software record lockout feature is disabled recording enabled Front panel lockout The front panel buttons on the Rerun Rackmount can be locked to prevent tampering with a running show The ability to lock out the front panel is disabled by default To enable or disable the ability to lock the front panel do the following 1 Start playing any show 2 Pause the show at any point 3 Pr...

Страница 12: ...fault When enabled the grand master feature does not alter the levels of the incoming DMX512 levels LIMITED MANUFACTURER S WARRANTY Products manufactured by Doug Fleenor Design DFD carry a five year parts and labor warranty against manufacturing defects It is the customer s responsibility to return the product to DFD at the customer s expense If covered under warranty DFD will repair the unit and ...

Отзывы: