Please
do
not
attempt
to
mount
the
S
‐
250
‐
12
within
the
Cool
Dome
itself,
due
to
the
large
amount
of
heat
created
by
the
power
supply,
will
greatly
reduce
the
cooling
effect
of
the
D2
Cool
Dome’s
heat
pump.
High
Voltage
A/C
Typical
Conventions,
single
phase:
Color
Symbol
Description
Black
L
Line
Conductor,
aka:
“Hot”
wire
White
N
Neutral
Conductor
Green
G
,
Ground
Wire,
Chassis
Ground
Low
Voltage
conventions,
D/C,
direct
current:
Color
Symbol
Description
Red
V+
Positive
conductor
Black
V
‐
Negative
conductor
The
output
of
the
S
‐
250
‐
12
external
power
supply,
can
be
adjusted
up
and
down
10%.
It
is
recommended
to
keep
the
voltage
at
the
D2
adjusted
to
at
least
11.5
vdc,
but
no
more
than
13.0
vdc.
By
running
the
enclosure
higher
than
13.0
vdc
may
cause
premature
component
failure.
It
is
best
to
check
and
tune
the
voltage
at
the
Cool
Dome
with
a
voltage
meter
at
the
time
of
installation,
and
use
the
adjustment
screw,
located
on
the
S
‐
250
‐
12,
to
the
right
side
of
the
terminal
screws,
to
raise
or
lower
the
output
voltage.
For
all
outdoor
wiring,
always
use
an
outdoor
rated
wiring,
or
wiring
in
weather
rated
conduit,
out
from
power
supply,
into
the
Cool
Dome.
Follow
all
local
and
applicable
wiring
and
safety
standards.
Please
keep
D/C
wire
runs
short
,
to
reduce
low
voltage
line
drop.
Also,
the
suggested
wiring
gauge
table
is
provided
to
further
prevent
low
voltage
line
drop,
and
to
guide
you
in
selecting
the
proper
wire
gauge
for
the
dc
run
from
the
power
supply
to
the
cool
dome.
It
is
always
advisable
to
use
a
drip
loop
on
all
wiring
going
directly
into
the
D2
enclosure,
to
reduce
the
risk
of
water
entering
and
damaging
internal
components.
All
fittings
and
seals
must
be
firmly
tightened
and
sealed,
before
placing
the
D2
in
service.
Inside
the
D2
we
have
provided
a
convenient
Screw
cage
clamp
style
terminal
blocks
to
wire
the
12
vdc
positive
(V+),
and
the
12
vdc
Negative
(V
‐
)
terminal.
Please
strip
the
insulation
off
the
last
3/8”
of
the
wires
and
fasten
wiring
securely
to
terminal,
using
a
small
blade
screwdriver
to
tighten
the
caging
mechanism
on
the
terminal
blocks.
Please
be
especially
attentive
to
wire
using
the
Proper
Polarity,
so
as
not
to
damage
the
internal
components,
or
damage
your
camera
within.
12
amps
12
Volts
D/C
Voltage
Drop
for
Dotworkz
D2
Cool
Dome
Wire
guage
In
AWG
(below)
Distance
(ft)>>
1.0 ft
10.0
20.0
30.0
40.0
50.0
100.0
4.0
0.006
0.062 0.124 0.186 0.248 0.310 0.620
6.0
0.010
0.098 0.196 0.294 0.392 0.490 0.980
AWG 8.0
0.016
0.156 0.312 0.468 0.624 0.780 1.560
10.0
0.025
0.248 0.496 0.744 0.992 1.240
2.480
12.0
0.040
0.400 0.800 1.200
1.600
2.000
4.000
14.0
0.063
0.628
1.256
1.884
2.512
3.140
6.280
Gauge
Multiplier
Vdc
drop/ft
Voltage
drop
(vdc)/
distance
(ft)
Acceptable line drop for Wire