![Dot Hill Systems SANnet II 200 FC Скачать руководство пользователя страница 25](http://html1.mh-extra.com/html/dot-hill-systems/sannet-ii-200-fc/sannet-ii-200-fc_installation-operation-and-service-manual_2524268025.webp)
Chapter 1 Product and Architecture Overview
1-5
Note –
Although the products are very similar in appearance and setup, the
configurations have very important differences. While the FC array can be used for all
applications, the SATA and SATA SE arrays cannot. Inappropriate use of the SATA
arrays in applications for which the FC array was designed might result in loss of data
and/or loss of data access.
Table 1-1
Comparison of SANnet II 200 FC, SATA, and SATA SE Array Features
SANnet II 200 FC Array
SANnet II 200 SATA Array
SANnet II 200 SATA SE Array
Applications
Best suited for
production applications
where the superior
features of FC technical
characteristics and
performance are
required. This includes
online applications such
as:
• Database
• Decision support
• Data warehousing
• Electronic commerce
• Enterprise resource
planning
• Messaging, file, and
Best suited for inexpensive
secondary storage applications
that are not mission critical
where higher capacity drives
are needed, and where lower
performance and less than
7/24 availability is an option.
This includes near-line
applications such as:
• Information lifecycle
management
• Content addressable storage
• Backup and restore
• Secondary SAN storage
• Near-line DAS storage
• Static reference data storage
Best suited for inexpensive
secondary storage applications
that are not mission critical
where higher capacity drives
are needed, and where lower
performance and less than
7/24 availability is an option.
This includes near-line
applications such as:
• Information lifecycle
management
• Content addressable storage
• Backup and restore
• Secondary SAN storage
• Near-line DAS storage
• Static reference data storage
Disks
Fibre Channel disks:
36, 73, or 146 GB at
10K RPM
36 or 73 GB at 15K
RPM
SATA disks:
250 GB at 7200 RPM
400 GB at 7200 RPM
SATA disks:
250 GB at 7200 RPM
400 GB at 7200 RPM
Maximum FC
Host Ports
per I/O
Controller
Module
4
(one SFP port each for
channels 0, 1, 4, and 5)
6
(two SFP ports each for
channels 1 and 0; one SFP
port each for channels 4 and
5)
6
(two SFP ports each for
channels 1 and 0; one SFP
port each for channels 4 and
5)
Maximum
Number of
Expansion
Units
Connected to
a RAID
Array
15
15
0
Содержание SANnet II 200 FC
Страница 10: ...x SANnet II 200 FC SATA and SATA SE Array Installation Operation and Service Manual March 2005...
Страница 14: ...xiv SANnet II 200 FC SATA and SATA SE Array Installation Operation and Service Manual March 2005...
Страница 36: ...1 16 SANnet II 200 FC SATA and SATA SE Array Installation Operation and Service Manual March 2005...
Страница 48: ...3 4 SANnet II 200 FC SATA and SATA SE Array Installation Operation and Service Manual March 2005...
Страница 82: ...4 34 SANnet II 200 FC SATA and SATA SE Array Installation Operation and Service Manual March 2005...
Страница 98: ...5 16 SANnet II 200 FC SATA and SATA SE Array Installation Operation and Service Manual March 2005...
Страница 118: ...7 10 SANnet II 200 FC SATA and SATA SE Array Installation Operation and Service Manual March 2005...
Страница 140: ...8 22 SANnet II 200 FC SATA and SATA SE Array Installation Operation and Service Manual March 2005...
Страница 146: ...A 6 SANnet II 200 FC SATA and SATA SE Array Installation Operation and Service Manual March 2005...
Страница 170: ...E 4 SANnet II 200 FC SATA and SATA SE Array Installation Operation and Service Manual March 2005...
Страница 210: ...6 SANnet II 200 FC SATA and SATA SE Array Installation Operation and Service Manual March 2005...