AssuredSAN Ultra48 Series Setup Guide
91
D
USB device connection
Rear panel USB ports
AssuredSAN Ultra48 Series controllers contain two different USB (universal serial bus) management
interfaces: a
Host
interface and a
Device
interface. Both interfaces pertain to the Management Controller
(MC). The Device interface is accessed via a port on the controller module face plate. The Host interface
(USB Type A)—reserved for future use—is accessible from the midplane-facing end of the controller module
(see
on page 22), and its discussion is deferred.
This appendix describes the port labeled CLI (USB Type B), which enables direct connection between a
management computer and the controller, using the command-line interface and appropriate cable (see
USB CLI port
Figure 47
USB device connection — CLI port
AssuredSAN Ultra48 Series controllers feature a USB CLI port used to cable directly to the controller and
initially set IP addresses, or perform other configuration tasks. The USB CLI port employs a mini-USB Type B
form factor, and requires a specific cable and additional support, so that a server or other computer
running a Linux or Windows operating system can recognize the controller enclosure as a connected
device. Without this support, the computer might not recognize that a new device is connected, or might
not be able to communicate with it.
For Linux computers, no new driver files are needed, but a Linux configuration file must be created or
modified (see
on page 93). For Windows computers a special device driver file,
gserial.inf
, must
be downloaded from a web site, and installed on the computer that will be cabled directly to the
Emulated serial port
Once attached to the controller module, the management computer should detect a new USB device.
Using the Emulated Serial Port interface, the Ultra48 Series controller presents a single serial port using a
customer vendor ID
and
product ID
. Effective presentation of the emulated serial port assumes the
management computer previously had terminal emulator installed (see
). Serial
port configuration is unnecessary.
IMPORTANT:
Certain operating systems require a device driver or special mode of operation to enable
proper functioning of the USB CLI port (see
Device driver/special operation mode
CACHE
LINK
DIRTY
LINK
ACT
CLI
CLI
Host Interface
Not Shown
SERVICE−2
SERVICE−1
6Gb/s
Connect USB cable to CLI
port on controller face plate
Содержание AssuredSAN 4544
Страница 8: ...8 Figures ...
Страница 10: ...10 Tables ...
Страница 14: ...14 About this guide ...
Страница 50: ...50 Connecting hosts ...
Страница 52: ...52 Basic operation ...
Страница 70: ...70 Troubleshooting ...
Страница 90: ...90 Electrostatic discharge ...
Страница 94: ...94 USB device connection ...
Страница 96: ...96 SFP option for CNC ports ...
Страница 100: ...100 Index ...