background image

9

8

 

        

 

 
 

                                  

 

 
 
 
 
 
 
 
 
 
 
 
 

9  

10 

11 

5.1. LCD Display

1.   CO

2

/TEMP/RH Chart 

2.   Max Reading of Chart 

3.   Min Reading of Chart 

4.   Micro SD Card

5.   Audible Alarm On/Off 

6.   Date and Time

7.   Temperature Reading 

8.   RH Reading  

9.   Main Menu 

10.  CO

2

-Reading 

11.  Zoom Level of Time 

 

 

(indicates the chart’s span

 

of time)

5.2 Trend Chart 

The trend chart (1) displays the past readings for CO

2

 and temperture and RH parameters. 

That can be toggled by using DOWN key: CO

2

, TEMP, RH. As show below:

5.3 Trend Chart Zoom 

Below is a table that show the available Zoom Levels for all parameters, as well as the duration of 

each division for corresponding Zoom Levels:

 

Using UP will toggle the available Zoom Levels for each parameters. Note that in addition to the Zoom 

Levels for each paramete. 

Zoom Level 

(Time Span) (11)

Time Per Division 

1MIN (minute) 

5sec /div 

1HR (hour) 

5m/div 

1Day (day) 

2h/div 

1WEEK(week) 

0.5d/div 

5.4 Max/Min 

At the top right corner of the display, there are two numerical indicators: Max (2) and Min (3). As the 

Zoom Level is changed, the Max and Min values will reflect the maximum and minimum values on the 

chart of the selected CO

2

 parameter. At startup, the unit will automatically display values for CO

2

 

5.5 Real Time 

The real-time (6) display at the top right corner of LCD, user can adjust date and time by enter TIME mode.

5.6 SD Card For Logger 

The device will record data logger by SD card while it existed. It’s can record Date, Time, CO

2

,  

Tempereture, RH, user can check and download logger by SD card reader. 

5.7 Main Menu Functions 

The Main Menu (9) functions can be toggled through by using MENU. If the main menu is not brought 

up, the green bar will remain blank, leaving the UP / DOWN buttons to toggle between parameters and 

Zoom Levels, respectively.

 

Pressing MENU once will bring up the main menu, with a flashing bar indicating the current choice. 

To select the function, press ENTER when the bar flashing over the current choice. Note that after 

1 minute if nothing is pressed, the Main Menu will disappear and the device will revert to the normal 

state.

HOLD HOME 

To revert to start up settings at any point, hold ENTER for 3 sec until an audible beep. The device will 

revert to Home Setting, displaying “Back Home done.” Note that this is not the same as Restore to 

factory settings. 

Below is a table showing what main menu selection is made by pressing MENU multiple times as 

well as their functions. Note that the device will display “Done,” followed by the confirmed selection if 

selected correctly.

 

 

        

 

 
 

                                  

 

 
 
 
 
 
 
 
 
 
 
 
 

9  

10 

11 

Function 

Directions 

ALARM 

When ALARM is set ON, an audible alarm will resound if the CO

2

 level exceeds 

varying levels (depending on border lever set) . Once ALARM is selected (by 

pressing ENTER), use either UP or DOWN to toggle the selection from ON to OFF 

or vice versa. Press ENTER one more time to confirm. A regular bell icon will be 

displayed if alarm is on; a silenced bell icon will appear on the screen if the alarm 

is set to be off. 

TIME 

This function allows the user to adjust the real-time, once TIME is selected, use 

UP and DOWN to adjust the current date and time, Press ENTER to comfirm. 

LOG 

This feature allows the user to see historical data recorded in the log at any point 

that is displayable on the chart. First make sure the desired Zoom Level is 

 

selected before enabling this function. Then once LOG is enabled, use UP and 

DOWN toggle between the time divisions to see all parameters’ measurements for 

each division. Press ENTER once more to exit this mode. 

CALI 

Use this function to calibrate your device with outside atmospheric CO

2

 level ~ 

400ppm. Select this mode, hold ENTER for 3 seconds until a beep and the chart 

will read “Calibrating”, then place the device outside for 20min. To escape, press 

MENU. Make sure the device is far from a source of CO

2

, not in direct sunlight, 

and not exposed to water. 

Содержание Air Co2ntrol 5000

Страница 1: ...n Micro SD Karte CO2 Monitor with Data logger function Micro SD card 5020 0111 www dostmann electronic de Bedienungsanleitung 2 Operating Instruction 7 CO2 Monitor mit Datenloggerfunktion Micro SD Karte CO2 Monitor with Data logger function Micro SD card ...

Страница 2: ...Micro USB Kabel Bedienungsanleitung Netzteil für USB Kabel Micro SD Karte 4 Funktionen im Überblick CO2 Anzeige Bargraphanzeige für den Verlauf Variable Zoomfunktion für Bargraph 2 Kanal NDIR Sensor Daten Logger Funktion via SD Karte Echtzeituhr 3 Farben LED Ampel 5 Bedienung des Gerätes Inbetriebnahme Nach dem Auspacken das Gerät mit Netzteil via USB Kabel verbinden Sobald die richtige Spannung a...

Страница 3: ...der HI Grenzwert auswählen und mit der ENTER Taste bestätigen Der jeweiles angezeigt Wert wieder mit den Pfeiltasten ändern und mit der ENTER Taste bestätigen Bis LOW Wert grüne LED Ab LOW Wert gelbe LED AB HI Wert rote LED Signalton wenn Alarm Funktion aktiviert ist Funktion Beschreibung ALARM Wenn die Alarmeinstellung aktiv ist ON ertönt ein akustischer Alarm wenn der eingestellte Grenzwert über...

Страница 4: ...ogen wurde Index 1 Introduction 7 2 Kindly note 7 3 Delivery contents 7 4 Features at a Glance 7 5 Bedienung des Gerätes 5 1 LCD Display 8 5 2 Trend Chart 8 5 3 Trend Chart Zoom 8 5 4 Max Min 9 5 5 Real Time 9 5 6 SD Card For Logger 9 5 7 Main Menu Functions 9 1 Introduction Dear Sir or Madam Thank you very much for purchasing one of our products Before operating the data logger please read this m...

Страница 5: ...the current choice To select the function press ENTER when the bar flashing over the current choice Note that after 1 minute if nothing is pressed the Main Menu will disappear and the device will revert to the normal state HOLD HOME To revert to start up settings at any point hold ENTER for 3 sec until an audible beep The device will revert to Home Setting displaying Back Home done Note that this ...

Страница 6: ...rs USB connection is for power supply only no communication with PC Unplugging the device may result in loss of most recent logged data on the chart This device is not intended for workplace hazard CO2 monitoring nor intended as a definitive monitor for human or animal health institutions life sustenance or any medical related situation We and the manufacturer assumes no responsibility for any dam...

Страница 7: ...errors and misprints reserved Reproduction is prohibited in whole or part Stand01 1709CHB DOSTMANN electronic GmbH DOSTMANN electronic GmbH Mess und Steuertechnik Waldenbergweg 3b D 97877 Wertheim Reicholzheim Germany Phone 49 0 93 42 3 08 90 Fax 49 0 93 42 3 08 94 E Mail info dostmann electronic de Internet www dostmann electronic de ...

Отзывы: