SYMPTOM
CAUSE
SOLUTION
Dosing
Under-dosing
Airtightness problem.
1. Check the tightness of
the hose clamps on the
dosing assembly.
2. Check the condition of
the suction hose.
Suction valve seal worn
or dirty.
Clean or replace it.
Excess flow (cavitation)
Reduce the flow rate
Worn plunger seal
Replace it
Scratched dosing pump
body
Replace it
Leaks
Leaks near the
fixing nut under
the pump body.
Dosing body seal
damaged, wrongly
positioned or missing.
Position it correctly or
replace it.
Leaks between
the dosing
adjustment
sleeve and the
dosing locking
nut.
Dosing pump body
seal damaged, wrongly
positioned or missing.
Position it correctly or
replace it.
Leaks between
the body and top
cover.
Top cover seal damaged,
incorrectly fitted or
missing
Position it correctly, clean
the seal seat or replace
the seal.
DOSATRON INTERNATIONAL
DECLINES ANY LIABILITY FOR ANY DAMAGE
RESULTING FROM IMPROPER USE.