DOSATRON INTERNATIONAL S.A.S /
13
©
DOSATRON INTERNATIONAL S.A.S /
14
US
SPECIFICATIONS
D14WL3000
D14WL3000IE
D14WL2
Operating
flow range
:
1/3 US Pint/min - 14 US GPM
[10 l/h mini 3 m
3
/h maxi].
Maximum
operating temperature : ............................
104 °F
[40 °C]
Operating
pressure
:
PSI
bar
4.3 - 85
0.30 - 6
7.3 - 85
0.50 - 6
4.3 - 85
0.30 - 6
Externally adjustable
or fixed
injection rate
:
Ratio
%
1:3000 - 1:333
0.03 - 0.3
1:3000 - 1:333
0.03 - 0.3
1:500 - 1:50
0.2 - 2
Concentrated additive injection :
US GPM - MAXI
US Fl. oz/min - MINI
Mini l/h - Maxi l/h
0.04
0.0017
0.003 - 9
0.04
0.0017
0.003 - 9
0.28
0.011
0.02 - 60
Connections
(NPT/BSP male) : ..................................
3/4”
[Ø 20x27 mm].
Hydraulic motor capacity
(for every 2 clicks of the piston) :
around
0.14 US Gallons
[0.53 l]
NOTE: The Dosatron is not preset,
see chapter DOSING SETTING
UNIT SIZE
Diameter : " [cm]
4 7/16
[11.2]
4 7/16
[11.2]
4 7/16
[11.2]
Total height :
"
[cm]
21
[53]
22 1/9
[56.16]
15/16
[50.7]
Width :
"
[cm]
6 5/16
[16]
10 10/41
[26.02]
6 5/16
[16]
Weight : ±
lbs
[kg]
3.5
[1.6]
5.3
[2.4]
3.7
[1.7]
SHIPPING CONTENTS:
1 DOSATRON / 1 mounting bracket for
DOSATRON / 1 suction tube of concentrated additive / 1 strainer /
1 injection suction tube for “IE” model / 1 owner’s manual
PACKAGE SIZE:
21 7/8" x 6 5/8" x 5 3/4" [55.2 x 16.5 x 14.5 cm]
PACKAGE WEIGHT:
~ 4.4 - 8.8 US lbs [ 2 - 4 kg approx]
DOSATRON Technology
Motor piston
Clear water
Solution water
+ % additive
Dosing piston
Adjustment (%) ratio
Concentrated
additive to be
dosed
A unique technology associating all dosing functions
Installed directly in the water supply line, the DOSATRON operates
by using water pressure as the power source. The water activates the
DOSATRON, which takes up the required percentage of concentrate.
Inside the DOSATRON, the concentrate is mixed with the water. The
water pressure forces the solution downstream. The dose of concen-
trate will be directly proportional to the volume of water entering the
DOSATRON, regardless of variations in flow or pressure which may
occur in the main line.