3. Remove the air cap (1).
Rinsing
4. Keep collecting tray ready.
Fig. 10: Rinsing spray gun
5. Keep the spray gun slightly at an angle
above the collecting tray, nozzle pointing
towards the ground.
6. Rinse the spray gun with an appropriate
rinsing agent through the material con-
nection (3), until the rinsing agent runs
clean without any material residue. Use a
brush to carefully clean the nozzle holes
(2).
7. Ensure proper disposal of the exiting
material and rinsing agent.
8. Connect the compressed air hose to the
spray gun.
9. Operate trigger lever until no more rinsing
agent flows out.
Final work
10. Place the air cap (1).
11. Tighten cap nut (1).
7
Cleaning and maintenance
7.1
Safety recommendations
WARNING!
Danger of fire and explosion
Flammable materials can cause a fire or
an explosion.
– Ensure that the flashpoint of the
cleaning agent is at least 5 K above
the ambient temperature.
– Pay attention to the explosion group
of the material, cleaning and rinsing
agent.
– Ensure that technical ventilation and
fire protection equipment are in
operation.
– Do not use any sources of ignition
and no open light.
– Do not smoke.
– Observe the safety data sheets.
WARNING!
Risk of injury from unsuitable replace-
ment parts in explosive areas.
Replacement parts not compliant with
the specifications of the ATEX guide-
lines can cause explosions in an explo-
sive atmosphere. Serious injuries and
death can be the consequence.
– Use exclusively original replacement
parts.
WARNING!
Danger from harmful or irritant sub-
stances
If you come in contact with hazardous liq-
uids or vapors, serious injury or death
can be the consequence.
– Ensure the technical ventilation is
operational.
– Observe the safety data sheets.
– Wear specified protective clothing.
Cleaning and maintenance
12/2016
EcoGun 249 - MSG00014EN
12/40