![Dorner Aqua Pruf 7400 Ultimate Series Скачать руководство пользователя страница 13](http://html1.mh-extra.com/html/dorner/aqua-pruf-7400-ultimate-series/aqua-pruf-7400-ultimate-series_installation-maintenance-and-parts-manual_2523168013.webp)
851-620 Rev. A
13
Dorner Mfg. Corp.
7400 Ultimate Series End Drive Conveyors
Installation
4.
Check belt sag by measuring from the top of the return
(Figure 32)
. Belt sag should not exceed 4" (102 mm).
Follow steps 7 – 9 in the “Belt Installation” section on
page 11 to remove slack from the belt.
Figure 32
Conveyors Longer than 10 ft
(3048 mm)
Typical Connection Components
(Figure 33)
.
Figure 33
1.
Locate the section number sequence etched on each
section of frame
(Figure 34, item 1)
.
Figure 34
2.
Position the frame sections in the correct order.
3.
Connect the frame sections by bolting the hex post
connectors
(Figure 35, item 1)
between frame sections.
Be sure O-rings are seated properly on hex post and hex
screws prior to tightening of screws to avoid damage to
O-rings.
Figure 35
4.
Follow the installation process described in “Conveyors
up to 10 ft (3048 mm)” starting on page 6.
CAUTION
Belt sag should not exceed 4" (102 mm) from
the top of the returns.
1
M10 x 1.5 mm hex head cap screws (x4)
2
Connector hex rods (x2)
3
Conveyor frame
4
O-rings (x8)
(102 mm)
Up to 4"
3
4
1
2
CAUTION
Avoid damage to O-rings. Be careful not to
pinch or cut them.
1