location.
DO NOT
light or smoke cigarettes or other smoking materials while installing the EFV-TSO.
DO NOT
use matches, candles or any open flame to leak test gas connections.
DO NOT
use Teflon® tape or pipe sealant on any flare ends, as doing so will not provide a leak-free seal. Keep flare
end of fitting free of grease, oil and thread sealant.
DO NOT
use pipe wrenches for this installation. Pipe wrenches may damage or crack gas fittings. Use only an open
ended wrench on the flat surfaces of the fittings.
NEVER
loosen a connection after tightening – this may cause a leak. It is always better to tighten more if a leak is
detected. If fitting is installed improperly, remove fitting, reapply sealant and reinstall properly per instructions.
WARNING
!
IF AT ANY TIME DURING THIS INSTALLATION YOU SMELL GAS:
•
STOP
installation. Turn OFF the gas at the shut-off valve.
•
CALL LICENSED PLUMBER
to test for leaks and fix any problems.
• Do
NOT
use electrical equipment such as a fan to dissipate gas vapors. Electric motors will spark and can
ignite gas vapors, causing fire or explosion.
• LP gases are heavier than air and dissipate slower than natural or manufactured gases. LP gas, if released into
the home, may accumulate in low-lying areas such as basements or crawl spaces.
Installation Steps:
WARNING
!
• Installation, testing and service
MUST
be performed by a licensed plumber / qualified installer.
•
Read and follow ALL
safety, use, sizing, installation and care instructions and follow all building codes, construction
standards, appliance manufacturer recommendations and instructions, and applicable ANSI standards.
• Follow local codes or, in the absence of local codes, follow the National Fuel Gas Code, ANSI Z223.1/NFPA 54, National
Gas and Propane Installation Code, CSA B149.1, the International Fuel Gas Code, or the Uniform Plumbing Code.
1. Turn off gas to all appliances in the vicinity where the EFV-TSO is to be installed.
2.
TURN OFF
and
UNPLUG
the appliance.
3. Shut OFF the gas with the manual shut-off valve serving the appliance on the gas supply line. If a shut-off valve is not
present on the gas line,
STOP
and contact licensed plumber (A shut-off valve is not included with this EFV-TSO).
4. Disconnect existing gas connector and fittings (if present) from the gas supply manual shut-off valve as follows:
WARNING
!