To avoid injury, death, fire, explosion, gas leak or property damage
• Installation, testing and service
MUST
be performed by a licensed plumber / qualified installer.
•
Read and follow ALL
safety, use, sizing, installation and care instructions and follow all building codes, con-
struction standards, appliance manufacturer recommendations and instructions, and applicable ANSI standards.
•
ALWAYS
replace your appliance gas connector when installing an EFV-TSO.
•
DO NOT REUSE.
The EFV-TSO is intended for a single installation. If the downstream appliance or gas connector
is replaced, then replace this EFV-TSO.
•
NEVER
install the EFV-TSO directly to an appliance or appliance gas regulator
• The EFV-TSO attaches to the manual gas shut-off valve serving the appliance. (Gas shut-off valve must have a
female NPT thread for proper connection – attaching the EFV-TSO to any other manual shut-off valve will result
in gas leak).
• Installing the EFV-TSO in any location other than the manual gas shut-off valve will result in gas leak or appli-
ance failure, causing personal injury, death or property loss.
• The manual gas shut-off valve
MUST
be in the same room and readily accessible within 6 feet of the appliance.
•
ALWAYS
install EFV-TSO in easily accessible and well ventilated location.
NEVER
install in concealed
Examples of a Typical Appliance Installation
/ Ejemplos de una Instalación de Aparato Típica
Appliance Side Lado del aparato
Gas Supply Side Lado del suministro de gas
NUT
CONNECTOR
NUT
TUERCA CONECTOR
TUERCA
(Female Inside Threads)
(Roscado interno hembra)
ADAPTADOR MACHO
MALE ADAPTER
(Male Outside Threads)
(Roscado externo macho)
FEMALE ADAPTER
ADAPTADOR HEMBRA
OR O
SEALANT HERE ONLY
APLICAR SELLADOR SÓLO AQUÍ
SEALANT HERE ONLY
APLICAR SELLADOR SÓLO AQUÍ
SEALANT HERE ONLY
APLICAR SELLADOR SÓLO AQUÍ
VÁLVULA HEMBRA X HEMBRA
FIP X FIP VALVE
™
WARNING
!
Installing An
EFV-TSO (cont'd)