12-2020
dormakaba Canada Inc. RAC5 Lite Installation Guide – PK3736 | 15
4.2.3.4 Motion Detector
1.
Refer to Annex B for detailed wiring.
2.
Mount the device at the desired location and run a 4-condutcor cable from the motion detector relay’s
terminal block to controller PCB connector J8, pins 3 & 4.
3.
To power the motion detector, connect the +12V input of the motion detector to the red wire connecting
the +DC OUT terminal on the power supply and the 12V input of the controller PCB (J16, pin 1), as shown in
Annex B. Then, connect the GND input of the motion detector to the black wire connecting the -DC OUT
terminal on the power supply and the GND input on the controller PCB (J16, pin 2). The use of wire
connectors/caps is recommended to ensure reliable electrical connections.
4.2.3.5 Fire Alarm Panel
1.
Refer to Annex B for detailed wiring.
2.
Remove the jumper wire connected between pins 3 and 4 of connector J18 on the controller PCB and
complete the fire panel installation as per manufacturer’s indications.
4.2.4 Install Strain Relief Bushing (For Power Adapter Only)
One strain relief bushing is provided in the hardware bag to secure the power adapter cable leading into the
RAC5 Lite enclosure to help prevent the possibility of wire tampering.
Figure 9 – Enclosure
1.
Remove the keyhole knock-out on from the inner side of the enclosure using a hammer and screwdriver or
awl to tap out the small metal disc.
2.
Determine the routing needed for the wiring of the power adapter from the AC power source to the
enclosure.
3.
Open the strain relief bushing and route the power adapter cable in. Leave enough cable length to plug
the power adapter’s connector into the power jack inside the enclosure. To obtain the desired strain relief
effect, firmly close the plug of the bushing onto the flat cable.
4.
Attach the strain relief bushing with cable onto the enclosure and connect the power adapter’s connector
to the power jack on the inside of the enclosure.
5.
If using the International Power Adapter, attach the appropriate AC outlet prong to the power adapter.