Dormakaba RAC5 Lite Скачать руководство пользователя страница 1

RAC5 Lite

Installation Guide

RAC Install Guide Covers.qxp_Layout 1  2021-01-26  3:48 PM  Page 3

Содержание RAC5 Lite

Страница 1: ...RAC5 Lite Installation Guide RAC Install Guide Covers qxp_Layout 1 2021 01 26 3 48 PM Page 3 ...

Страница 2: ... 1 2 Cables not shown 8 3 1 3 Card Reader s 8 3 1 4 Locking Device 8 3 1 5 Power Adapter 8 3 1 6 Other Peripherals optional 8 3 1 7 Programming Device 9 3 1 8 Installation Hardware Bag 9 3 1 9 Tools Required not supplied 9 3 2 Exploded View 10 4 System Installation Overview 10 4 1 Pre installation Procedures 11 4 2 Installation and Wiring Procedures 12 4 2 1 Mount the Enclosure 12 4 2 2 Mount the ...

Страница 3: ... Auditing 16 5 3 Power Failure 17 5 4 Loading Recommendations 17 5 5 System Deactivation 17 6 Annex A Wiring Diagram and Tables 18 7 Annex B Peripheral Wiring Diagrams 19 8 Annex C Electromagnetic Interference 24 9 Annex D Quick Troubleshooting Guide 25 9 1 Power Troubleshooting 25 9 2 Card Reading Troubleshooting 25 9 3 External Inputs Troubleshooting 26 9 4 Locking Device Troubleshooting 26 9 5 ...

Страница 4: ... should always be installed in a secured room or facility with controller access to prevent access to the system Card reader or other peripheral installations within elevators must only be done with prior consultation of the elevator manufacturer A technician from the elevator manufacturer should always be present for installation Do not connect to a receptacle controlled by a switch If installing...

Страница 5: ...rference to radio communications However there is no guarantee that interference will not occur in an installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna ...

Страница 6: ...eader mounts directly on doorframes as narrow as 2 inches 5 1 cm while the insert card reader can only be installed in an elevator panel The RAC5 Lite is a simple access control solution for a dual card reader providing features as per the feature list below See Figure 1 for a typical configuration Figure 1 RAC5 Lite System Features Variable access delay Relay Outputs x2 Power failure 3 way auto r...

Страница 7: ... 3 RAC5 Lite Controller Box A RAC5 Lite Enclosure Access Door Holds the controller board PCB and the power adapter jack Knockouts are available on 3 sides for routing of peripheral cables B Controller Board PCB Controls all the features of the RAC5 Lite system C DC Power Jack Used for connecting to the 12 VDC power adapter to provide power to the controller PCB D Cam lock with Key To provide secur...

Страница 8: ...rds and or mobile phone credentials Figure 4 Contactless Card Reader 2 2 3 Locking Devices The RAC5 Lite controller PCB provides a single relay output that can be used to control an Electric Strike G or Electromagnetic Lock H as shown in Figure 5 Figure 5 Electric Strike Electromagnetic Lock 2 2 3 Optional Peripherals The RAC5 Lite can also be used with the following peripherals Exit Devices Motio...

Страница 9: ...cables Controller PCB to adapter jack and controller PCB jumpers card reader type dependent 3 1 3 Card Reader s F Contactless reader see Figure 4 3 1 4 Locking Device NOTE Locking device s dependent on the system configuration ordered G Electric strike H Electromagnetic lock 3 1 5 Power Adapter NOTE Dependent on the countries electrical power requirements I 1x North America 12 VDC output power ada...

Страница 10: ...relief connector with locking nut S 1x Strain relief bushing T 2x Diode rectifier U 5x Steel flat washer 8 V 3x Crimp terminal B connector 3 1 9 Tools Required not supplied Safety glasses Electric drill 9 64 3 5 mm drill bit 7 32 5 5 mm drill bit 1 4 6 5 mm drill bit 3 8 9 5 mm drill bit Philips screwdriver 2 Slotted screwdriver 3 32 tip width Adjustable wrenches Crimp tool 18 22 AWG Pliers Wire c...

Страница 11: ...llations and wiring of RAC5 Lite enclosure peripherals must comply with all applicable local building codes and regulations and National Electric Code ANSI NFPA 70 Do not connect power to the enclosure until the end of the installation process If installing the RAC5 Lite in an elevator cage environment or in proximity to any other equipment that may generate high levels of electromagnetic interfer...

Страница 12: ... adequate clearance for the card being presented to the reader For remaining peripherals Determine the location s required for any other peripherals REX motion detector etc and ensure that all required cabling is available as required in the following steps Install as per manufacturer s instructions and route wires to the RAC5 Lite enclosure for connection to the controller PCB 3 Set the desired a...

Страница 13: ...etting SW3 a OFF One locking device b ON Two locking devices Test Mode switch setting SW4 a OFF Normal operation b ON Test mode 4 2 Installation and Wiring Procedures 4 2 1 Mount the Enclosure Install the enclosure in the desired location using the appropriate items from the hardware bag NOTE For easier access we recommend removing the access door prior to installation Figure 8 Enclosure ...

Страница 14: ... Connect the included cable to the terminal block of the reader as shown in Annex A Ensure the correct wire colour is attached to the correct terminal block connection 4 Route the card reader s wire through the grommet of the back plate and assemble the front of the reader onto the back plate Assemble by tightening down the screw provided in the card reader s installation bag on the bottom of the ...

Страница 15: ...ecommendations as well as local building codes 2 Install and route a 2 conductor cable from the controller PCB to the desired location of the electric strike or electromagnetic lock 3 If installing an electric strike install the diode across the terminals of the locking device using the crimp connectors provided in the hardware bag if needed Do not reverse the diode polarity as indicated on the wi...

Страница 16: ...CB and complete the fire panel installation as per manufacturer s indications 4 2 4 Install Strain Relief Bushing For Power Adapter Only One strain relief bushing is provided in the hardware bag to secure the power adapter cable leading into the RAC5 Lite enclosure to help prevent the possibility of wire tampering Figure 9 Enclosure 1 Remove the keyhole knock out on from the inner side of the encl...

Страница 17: ...y the Fire Alarm Input is properly connected or a jumper wire is connected 5 De activate the bypass switch SW3 and SW5 on the controller board B 6 If a Request to Exit REX button is connected press it and verify that the door unlocks Verify the door unlocks for 5 seconds delay is configurable and then relocks afterwards 7 If a Remote Unlock button is connected press it and verify that the door unl...

Страница 18: ...ioning and the on board relay will return to its normal state Any peripheral connected to the relay will then be either in a Normally Open NO or Normally Closed NC state dependent on the wiring 5 4 Loading Recommendations Do not exceed the load limitations of the control panel The maximum recommended load for the output relay in the RAC5 Lite system is 1 Amp at 30 VDC The current supplies by the c...

Страница 19: ... all connected to dry terminals NC NO with a common connection to the Ground terminal on each of the connectors dry terminals must be able to sink minimum 25mA at a minimum of 5V rating J1 is rated for an output of 12V 200mA J6 J18 are rated for outputs of 12V 600mA Controller Board RAC5 Peripherals Connections Controller Board Peripheral Signal PCB Conn Wire Conn Description REM UNL J8 pin 1 Remo...

Страница 20: ...k White Green 1 2 3 4 1 2 3 4 1 2 3 4 J3 J7 J8 J12 J1 J15 J16 J6 J18 J19 RAC5 LITE PCB NO NC CO M GND F IRE GND 12V _LCK 1 GND 1 2V NO NC CO M RE_UNL 2 GND RE_UNL 1 1 2 3 4 1 2 3 4 1 2 3 2 1 1 2 3 12_LCK 2 GND 1 2 3 4 PWRGND GND PWR RD 1 RD 2 READER 2 READER 1 1 2 3 4 J11 REX2 GND TAMPER GND DOOR STAT 2 GND GND REX 1 GND DOOR STAT 1 GND Maximum cable length of 1000 Feet ...

Страница 21: ...rike Wiring Fail Safe Fire Alarm Bypass Wire See Note 12V Supply For Locking Device Diode Strike Black Wires Connector Red Wire Black Wire Note To automatically unlock the door in case of fire remove the Fire Alarm Bypass wire and connect J18 to the Fire Alarm panel as per Fire Alarm Panel Wiring diagram see Annex B Figure 10 In this case the Electric Strike MUST be powered from the RAC5 Lite s 12...

Страница 22: ...CO M RE_UNL 2 GND RE_UNL 1 1 2 3 4 1 2 3 4 1 2 3 2 1 1 2 3 12_LCK 2 GND 1 2 3 4 PWRGND GND PWR RD 1 RD 2 READER 2 READER 1 1 2 3 4 J11 REX2 GND TAMPER GND DOOR STAT 2 GND GND REX 1 GND DOOR STAT 1 GND Figure 16 Externally Powered Locking Device Wiring 12V Only Locking Device Ground Locking Device Control External Power Supply GND 12V or 24V Output Voltage Note If the locking device is inductive su...

Страница 23: ...OM NO NC REX 1 EXIT COM NO NC REMOTE UNLOCK 1 EXIT COM NO NC REMOTE UNLOCK 2 1 2 3 4 1 2 3 4 1 2 3 4 J3 J7 J8 J12 J1 J15 J16 J6 J18 J19 RAC5 LITE PCB NO NC CO M GND F IRE GND 12V _LCK 1 GND 1 2V NO NC CO M RE_UNL 2 GND RE_UNL 1 1 2 3 4 1 2 3 4 1 2 3 2 1 1 2 3 12_LCK 2 GND 1 2 3 4 PWRGND GND PWR RD 1 RD 2 READER 2 READER 1 1 2 3 4 J11 REX2 GND TAMPER GND DOOR STAT 2 GND GND REX 1 GND DOOR STAT 1 GN...

Страница 24: ...When the RAC Lite is connected to a Fire Alarm Panel it must be connected to a Normally Closed dry contact output See Notes 1 and 2 1 2 3 4 1 2 3 4 1 2 3 4 J3 J7 J8 J12 J1 J15 J16 J6 J18 J19 RAC5 LITE PCB NO NC CO M GND F IRE GND 12V _LCK 1 GND 1 2V NO NC CO M RE_UNL 2 GND RE_UNL 1 1 2 3 4 1 2 3 4 1 2 3 2 1 1 2 3 12_LCK 2 GND 1 2 3 4 PWRGND GND PWR RD 1 RD 2 READER 2 READER 1 1 2 3 4 J11 REX2 GND ...

Страница 25: ...tor motors To prevent the unit from operational instability such as freezing or losing programming shielded cables should be used and connections made as per the diagram below Figure 20 Protection from Electromagnetic Interference 1 Use shielded cables for the reader 2 Connect the shield wire of the reader cable to the Ground wire 3 Connect the wires to the mounting screw of the RAC5 Lite Remove t...

Страница 26: ...cted properly to the power adapter as per Annex A Verify AC power is active for the wall mount power adapter If qualified with a multi meter verify that 12VDC is present across J16 1 and J16 2 with the power adapter connected and AC power turned on 9 2 Card Reading Troubleshooting Symptom Action No feedback on reader when using a card Verify that the RAC5 Lite controller is active If not reset the...

Страница 27: ...ON Verify the wiring to the locking device Locking Device does not unlock If the Locking Device Relay LED D31 D30 for the second device turns ON Verify the Fire Alarm input is not active input contact closed Fire Alarm LED D47 is on Verify the wiring to the locking device If a diode is installed on the locking device verify the polarity If the locking device Relay LED D31 D30 for the second device...

Страница 28: ...program or audit the RAC5 Lite Verify the RAC5 Lite controller is active The Heartbeat D46 should be blinking and Reader LED D48 D37 LEDs should be ON If not reset the RAC5 Lite controller Press the Reset Switch SW1 or disconnect and reconnect the power 10 Annex E Reader Drilling Template Figure 21 Reader Drilling Template not to scale ...

Страница 29: ...dormakaba Canada Inc www dormakaba us RAC Install Guide Covers qxp_Layout 1 2021 01 26 3 48 PM Page 4 ...