dormakaba ITS9613 and ITS9625 Installation Instructions
08279631
02-2020
ITS96 Concealed in Door Closers
7
Adjustments - hold open
Adjustments - spring force
3.3.1 Place the hold open mechanism in desired
position and tighten screw.
3.3.2 To adjust hold open force:
•
To increase = turn CW
•
To decrease = turn CCW
3.3.3 To enable: push white slide into hold open
mechanism.
3.3.4 To disable: pull white slide away from hold open
mechanism.
3.3 Adjust hold open
Fig.8
Fig.9
Increase
Decrease
Barrier free openings:
Adjust only if more tension is
required to close and latch the door. Depending on
opening conditions, a door adjusted to meet barrier-
free forces may not have sufficient power to reliably
close and latch the door.
•
Decrease force:
turn counter-clockwise
•
Increase force:
turn clockwise
•
Max turns - 17
Closer size
Max door
weight (lbs)
Door width
Full turns
Interior
9613
2
100
2'6"
8
3
125
3'
15
4
150
3'6"
NA
5
175
4'
NA
9625
2
100
2’6”
NA
3
125
3’
-5
4
150
3’6”
0
5
175
4’
8
3.4 Adjust spring force