dormakaba ITS9613 and ITS9625 Installation Instructions
08279631
02-2020
ITS96 Concealed in Door Closers
4
Track
Main arm
2.1 Insert track components
2
Installation instructions
2.2.1 Place arm on closer according to hand of door.
2.2.2 Secure arm with pinion screw.
2.2.3 Close valve by turning completely clockwise.
2.2.4 Rotate arm 45° to preload.
2.2 Installing main arm
Fig.3
Fig.2
Deadstop
block
2.1.1 Thread screw a few turns into the deadstop
block.
2.1.2 Insert components into track as shown.
2.1.3 Fasten track to frame.
Deadstop
assembly
Hinge
Slide shoe
Hold open (optional)
NOTE: Arrows on hold open
and slie shoe, must point away
from hinge when installing in
track.
2 track brackets
(optional)
Part no. 08082820
Pinion
screw
Arm
Right hand
door
Left hand
door
5mm hex
key
45°
120°-0
°
7°-0°
3mm hex
key