background image

REVOLVING DOOR LOG BOOK

13

2021-10

Visit dat

e

W

ork

 Or

der

 /

 

A

ss

et number

S

er

vic

e in

formation /

W

ork

 c

arried o

ut

Te

st r

epor

t, de

fec

ts

  

if

 an

y and

  

requir

ed ac

tion

Name

C

ompan

y name

(o

f qualified

 

technician)

Signat

ur

e

Содержание GERYON

Страница 1: ...Important warranty user information and service record for your automatic door Revolving door operating maintenance manual For power operated doors to EN 16005 ...

Страница 2: ...venience and prolongs the life of the door operator There are also legal implications regarding the servicing of all door types which must be adhered to to ensure the safety of users at all times All safety requirements for power operated doors are stipulated in EN 16005 2012 Power operated pedestrian doorsets Safety in use All dormakaba service engineers are trained to comply with this standard t...

Страница 3: ...sfer any additional obligation to dormakaba regarding this product dormakaba standard terms and conditions will apply at all times and are available on request dormakaba are not liable for the consequences of any third party claim on its products which are sold in the knowledge that installation is carried out by competent staff and maintained in accordance with current safety standards Thank you ...

Страница 4: ...TC GERYON Other please state below delete as applicable Sales Order No Asset No Year of construction Commission date Installed by DORMA UK Ltd Other please state company Doorset location reference Additional information In order that an automatic door operator may comply with the requirements of EN16005 2012 a risk assessment should be carried out prior to installation which assesses the risk to u...

Страница 5: ...ion complete 3 2 Check safety equipment according to risk assessment to EN 16005 Finger protection crushing shearing and drawing in Safety sensors Sensor monitoring Reversing Stop equipment Safety screen Safety contact strips SCS Force limitation Emergency pushbuttons Safety sensors Fire alarm connection Batteries 3 3 Control elements Pushbuttons switches Contact mats Radio controls Remote control...

Страница 6: ...ace the test object CA in position A as shown in Fig 1 and verify that the door stops without hitting the test object Repeat with the test object in position B Bottom Rail pressure switch for each leaf if fitted With the door operating place the test object CB in position shown in Fig 2 Safety edge should touch test object and stop door without contact by door leaf Leading face sensor for each lea...

Страница 7: ...d stop Test by pushing the door in its direction of rotation fig 7 General tests Check there are no hazards due to crushing shearing impact and drawing in Check that the door speed is not likely to increase the risk of impact Check the door area does not present tripping or slipping hazards Check all door panels for broken cracked glass Check all doors have correct warning and information signs di...

Страница 8: ...trol and operating elements adjust repair or replace them if necessary 4 Check all the safety devices adjust repair or replace them if necessary 5 Check the additional options night closing emergency power supply door panel lock locking etc 6 Check the electrical voltages 7 Measure the operating forces check the deviation from the measurement during the initial commissioning 8 Check the wiring scr...

Страница 9: ...is arrival at site If it is not available then it is the responsibility of the facilities operator to record the visit REVOLVING DOOR LOG BOOK 9 2021 10 Visit date Work Order Asset number Service information Work carried out Test report defects if any and required action Name Company name of qualified technician Signature ...

Страница 10: ...VOLVING DOOR LOG BOOK 10 2021 10 Visit date Work Order Asset number Service information Work carried out Test report defects if any and required action Name Company name of qualified technician Signature ...

Страница 11: ...VOLVING DOOR LOG BOOK 11 2021 10 Visit date Work Order Asset number Service information Work carried out Test report defects if any and required action Name Company name of qualified technician Signature ...

Страница 12: ...VOLVING DOOR LOG BOOK 12 2021 10 Visit date Work Order Asset number Service information Work carried out Test report defects if any and required action Name Company name of qualified technician Signature ...

Страница 13: ...VOLVING DOOR LOG BOOK 13 2021 10 Visit date Work Order Asset number Service information Work carried out Test report defects if any and required action Name Company name of qualified technician Signature ...

Страница 14: ...VOLVING DOOR LOG BOOK 14 2021 10 Visit date Work Order Asset number Service information Work carried out Test report defects if any and required action Name Company name of qualified technician Signature ...

Страница 15: ...VOLVING DOOR LOG BOOK 15 2021 10 Visit date Work Order Asset number Service information Work carried out Test report defects if any and required action Name Company name of qualified technician Signature ...

Страница 16: ...tate Falkirk FK2 9HQ IRELAND PO Box 1050 Maynooth Co Kildare NORTH WEST Unit 10 Meadow Business Park Meadow Lane Bolton BL2 6PT dormakaba Kaba Ltd Lower Moor Way Tiverton Devon EX16 6SS LONDON NORTH SOUTH Wilbury Way Hitchin Hertfordshire SG4 0AB MIDLANDS NORTH EAST SOUTH WEST Lower Moor Way Tiverton Devon EX16 6SS Unit 32 Crowther Road Crowther Industrial Estate Washington Tyne Wear NE38 0AD The ...

Отзывы: