background image

Prosecure Opti Motion Stereo

2

DORMA

Adjusting the inclination angle

 

Position can be modified in 5° 
 increments. 
Holding the sensor’s baseplate  
by the sides, move it forward and 
position it as required. 

 

40°

Setting for an inclined detection area

Turn the PCB from -35° to +35° (horizontal movement) to 
adjust the detection range. The position can be modified in 
2.5°.

 

 

Detection area size/Sensitivity

Change the size of the detection area using the potentiometer.

min.

max.

 

mind. 
50 % 
max

Detection capabilities
Direction detection

  No direction recognition

  With forward direction recognition  

(towards the sensor)

  With backward direction recognition  

(away from the sensor)

Cross-traffic suppression

Cross-traffic suppression allows passers-by to be  partially 
suppressed.  
The detection field is reduced when this  option is set.

  Little cross-traffic, (1 ... 5) 

door  remains closed

  A lot of cross-traffic, (6 ... 10) 

door remains closed

Slow Motion

  Even the smallest of movements are detected.

"Door closed" setting

Door opens even when extremely slow-moving objects 
approach.

"Door open" setting

The door closes if no movement is detected within 
the monitoring time.

  Monitoring time/sensitivity:  

3 seconds, decreasing

  Monitoring time/sensitivity:  

5 seconds, constant maximum sensitivity

Immunity (1 ... 7)

Immunity can be used to minimize interference such as  
rain, vibration and reflections.

LED status display
Color indicator

Status

G

Green

Device ready for operation

R

Red

Detection active

G

Green flashing

Command received

R

Red flashing

Fault

R/G

Red/green flashing

Initialisation after switching on

 

Setup

Remove all objects from the door area that do not normally 
belong there. 
Switch on the device and wait 10 s  
(the red/green LED will flash).
Test the settings by walking near the detection area.
The red LED lights up when an object is detected.

Swing door applications

The sensor can be used on swing doors.
Mount the sensor approx. 20 - 30 cm above the door edge to 
the sides of the door hinges (hinge side) and activate cross-
traffic suppression. The closing door leaves are not  detected 
as a result.

Отзывы: