L6L
2. Assembly
23
4. Commissioning
SW101
6
Configuration protection
off
off
on
active
4.2 Reader settings
Hitag (PX10)
Legic advant-Leser (PX51)
Mifare DESfire-Leser (PX71)
SW101
1
2
3
4
5
6
7
8
Function
unused
1)
2)
3)
1)
Configuration protection
When configuration protection is activated, the configuration
cannot be changed or deleted.
SW101
1
2
3
4
5
6
7
8
Function
unused
Reader Function
unused
SW101
Reader Function
4
5
6
off
off
off
Indala-Trovan (Kombi)
off
off
on
Indala (Flexpass)
off
on
off
Trovan (TIMAC)
off
on
on
free
on
off
off
Trovan current customer (TIMAC)
on
off
on
free
on
on
off
Trovan (IPEV)
on
on
on
free
XX
XX
XXXXXXXXXX
3801
###
SW101
Number
Reader
3801415
HITAG (PX10)
3801400
Legic advant (PX51)
3801202
Mifare DESFire (PX71)
Indala-Trovan (PX15)
3801261
########
## ##
SW101
Number
Reader
3801261
Indala-Trovan (PX15)
The
configuration protection function
is only
available with firmware V3.30 or later.
2)
Interface
3) unused
Switch 6 is set ex works, and its position
should not be changed. An incorrect setting
can make the reader unusable!
Configuration protection may only be
deactivated if the "Load IdendAssembler"
system parameter is activated in DORMA
MATRIX.
SW101
7
Interface
off
OMRON operation
on
RENA operation