L6L

2. Assembly

11

2.6 Assembly of flat casing

Flush cabling

Once the preparatory work is complete, the pre-assembly 
plate can be fitted to the wall.

To do this, the three holes for the fixing screws must be  
drilled according to the drilling template included.

Before drilling, ensure that you will not be 
able to damage any cables or similar located 
underneath the plaster.

The cables are laid through the knock-out sections on the 
pre-assembly plate.
The data cables (RS485/DCW) must be stripped from 
approx. 15mm after the wall opening.
The shielding is shortened to approx. 10mm and clamped 
underneath the clips.

The clips are intended for connecting the data line shielding 
and are not used for strain relief.

The wires are then shortened to the required length and  
connected to the screw terminals (on the terminal printed 
card). The transformer is only fitted for the 230V models.

The cables are then inserted through the rear wall of the 
terminal and the terminal is screwed onto the pre-assembly 
plate using the three fixing screws.

Area for 
cable outlet

Contour of pre-assembly plate

ø6

164.5

142.5

27.7

approx. 1500

Lower casing edge

Top edge of finished floor

ø6

ø6

Transformer

Содержание L6L

Страница 1: ...DORMA Installation Manual Terminal L6L F1 F3 F4 F5 F6 F2 1 3 4 5 2 6 8 9 0 7 Es c F7 F9 F1 0 F1 1 F1 2 F8...

Страница 2: ...ep casing 12 2 8 Assembly using a wedge 13 3 Connection variants 14 3 1 External connections 14 3 2 Power supply 14 3 3 Emergency power supply optional 16 3 4 LAN interface 17 3 5 RS485 RS232 interfac...

Страница 3: ...pts no liability for the perfect functioning of the L6L in external non system environments Despite every effort to prevent mistakes they can never be completely avoided Therefore we would be grateful...

Страница 4: ...evant device safety standard for the unit are not negatively affected as this would reduce the safety level of the unit Before switching on ensure that the operating and control voltages connected do...

Страница 5: ...The connection to a host can be realised via either an LAN interface or an RS485 interface For connecting sub devices there is a DCW and an RS485 bus available 1 4 Further Sources of Information Furt...

Страница 6: ...template 1 x patch cable 30cm only for deep casings L6L A H D 1x B E G 3x 3x F 3x 3x DORMA Installation manual L6L C 1x F1 F3 F4 F5 F6 F2 1 3 4 5 2 6 8 9 0 7 Esc F7 F9 F10 F11 F12 F8 F1 F3 F4 F5 F6 F...

Страница 7: ...F1 F3 F4 F5 F6 F2 1 3 4 5 2 6 8 9 0 7 Esc F7 F9 F10 F11 F12 F8 Top section Bottom section Preassembly plate F1 F3 F4 F5 F6 F2 1 3 4 5 2 6 8 9 0 7 Esc F7 F9 F10 F11 F12 F8 F1 F3 F4 F5 F6 F2 1 3 4 5 2 6...

Страница 8: ...F5 F6 F2 1 3 4 5 2 6 8 9 0 7 Esc F7 F9 F10 F11 F12 F8 F1 F3 F4 F5 F6 F2 1 3 4 5 2 6 8 9 0 7 Esc F7 F9 F10 F11 F12 F8 F1 F3 F4 F5 F6 F2 1 3 4 5 2 6 8 9 0 7 Esc F7 F9 F10 F11 F12 F8 61 5 mm 101 mm Botto...

Страница 9: ...in the reverse order When working on the open casing it is advisable to lock the front using the front locking catch This tool can also be used to open the terminal Please note the following points D...

Страница 10: ...General Installation Guidelines The following assembly types are possible Deep casing Flush fit cabling standard Flush fit cabling connection of LAN and 230V using sockets Flat casing Flush fit cablin...

Страница 11: ...pped from approx 15mm after the wall opening The shielding is shortened to approx 10mm and clamped underneath the clips The clips are intended for connecting the data line shielding and are not used f...

Страница 12: ...onnecting the data line shielding and are not used for strain relief The wires are then shortened to the required length and connected to the screw terminals on the terminal printed card The transform...

Страница 13: ...he wall these need to be punched out First the 2 mounting holes required for fixing are drawn in accordance with the illustration below and drilled using a 6mm drill bit Before drilling ensure that yo...

Страница 14: ...8 RS232 3 2 Power supply 24V Terminals The power supply of the L6L is provided via a plug connector ST506 With the 24V terminals a voltage with 16V to 36V DC direct voltage or 16V to 24V AC alternatin...

Страница 15: ...nd a fuse element to protect against short circuits both already provided on site The earth conductor must be connected b Plug in connection deep casing only An earthing connection cable is used to co...

Страница 16: ...er failure depends on the configuration of the terminal Either the terminal goes into standby mode after an adju stable time and the terminal is reactivated by pressing the E key on the keyboard or th...

Страница 17: ...ace conforms to Ethernet standard IEEE 802 3 The CAT5 cable with RJ45 plug is inserted directly into the LAN connection at the top right of the basic module The ferrite hinged core included in the acc...

Страница 18: ...litated via the RS485 interface Up to 31 RS485 sub devices including a maximum of 16 readers can be connected Please note here that the total power consumption of the sub terminals does not exceed the...

Страница 19: ...connection to the host is being made via a modem the modem cable art no 1900004912392 is connected to ST508 RS485 For old devices e g VTxx M6 Box M6I M6T L6I the pin configuration is inverted For an...

Страница 20: ...me DCW components e g four readers can be connected In this case please ensure that the total power consumption of the sub terminals does not exceed the output of the terminal or power pack The termin...

Страница 21: ...diode shown is used as the recovery diode When connecting alternating current it must be replaced with an RC element or a Transzorb diode Art no 1900001662276 for interfe rence suppression 3 9 Digital...

Страница 22: ...rmissible voltage Input voltage under the minimum permissible voltage A manual reset has been triggered LED 401 flashing Meaning Data is being sent or received LED 402 on Meaning Remote terminal prese...

Страница 23: ...AC off on on free on off off Trovan current customer TIMAC on off on free on on off Trovan IPEV on on on free XX XX XXXXXXXXXX 3801 SW101 Number Reader 3801415 HITAG PX10 3801400 Legic advant PX51 380...

Страница 24: ...memory upgrade the capacity can be increased to 10 000 or 200 000 employees The memory upgrade can be ordered as an accessory Art No Description 1900070400134 Upgrade 1000 10 000 EMP 1900070400135 Upg...

Страница 25: ...le card needs to be replaced there is a spare fuse at the bottom right of the base module The fuse can be re ordered using art no 1900001797487 Littlefuse type 0454 002 2A The use of other fuses is no...

Страница 26: ...ly to the unit must remain switched on Please perform this work with great care to avoid triggering a short circuit Do not use any metallic tools for this work 5 1 3 Replacing the back up battery Inse...

Страница 27: ...L6L EG Konformit tserkl rung EC Declaration of Conformity CE D claration de conformit 27 L6L EG Konformit tserkl rung EC Declaration of Conformity CE D claration de conformit...

Страница 28: ...L6L 28 EG Konformit tserkl rung EC Declaration of Conformity CE D claration de conformit...

Страница 29: ...L6L EG Konformit tserkl rung EC Declaration of Conformity CE D claration de conformit 29...

Страница 30: ...DC SELV 30Veff AC SELV Digital inputs 3x optocouplers plus switching Max loading 10mA Switching thresholds active at 16 VDC or 15 VAC passive at 4 VDC or 4 VAC Display and operating elements 1x LC di...

Отзывы: