background image

Refer to PS501 Installation Instructions for complete wiring information.

AUXILIARY POWER OUTPUT

The ED 800 is equipped with an auxiliary power output terminal which can be used to power 
accessories such as electric strikes or radio frequency receivers.  This terminal provides a 
nominal 12 Volts DC filtered unregulated power source.  The voltage range is from 10 to 25 volts 
at 500 milliamps.  

More than one accessory can be powered by the auxiliary power output 

terminal, however the combined power draw can not exceed 500 milliamps.

ED800-25

ED800

    12 VDC
ACCESSORY

ED800 

BUSY SWING (SAFETY)

GROUND

NC

C

VESTIBULE

+12VDC

 OPEN TRIGGER

12

3

6

45

7

8

ES-105

ES5000 SERIES

INPUT B

FIRE

CONTACT

-

(2X) 16AMP SURGE, .2 SEC.

(2X) 24VDC, 1AMP

PS 501 POWER SUPPLY

24VDC

OUTPUTS

  A

+

-

 B

+

CONTACT

INPUT A

ADJ

U

STM

E

NT

DEL

A

Y

FIRE

1

2

CONTACT

DRY

3

4

5

INPUT

OUT

P

UT

 B

120 VAC

DIP SWITCH

OUT

P

UT

 A

8

DRY

CONTACT

6

7

OFF

ON

IN

P

U

T

POWER 

TRANSFER

EXIT DEVICE

Typical wiring diagram for the ED800 with
PS501 Power Supply and ES5000 or ES9000
Exit Device.

BUSY SWING (SAFETY)

 OPEN TRIGGER

1

VESTIBULE

C

46

7

NC

8

5

3

2

+12VDC

GROUND

-

+

NO

NO

+12VDC

8

 OPEN TRIGGER

BUSY SWING (SAFETY)

NO

C

NC

VESTIBULE

GROUND

27

56

34

12

Refer to ES100 Installation Instructions for complete wiring information.

 

ES100 
POWER SUPPLY

(+)

TURN OFF 120 VAC POWER BEFORE

MAKING ANY CONNECTIONS OR SERVICE.

(-)

ZONE 1

OUTPUT

TERMINALS

24 VDC

(+)

CONTROL

SWITCH

(IN)

1

2

3

4

(+)

(-)

ZONE 2

24 VDC

TERMINALS

OUTPUT

(+)

SWITCH

CONTROL

(IN)

5

6

7

8

CONNECTIONS

NO

10

9

11

ES8000

EXIT DEVICE

Typical wiring diagram for the ED 800 with ES100 
Power Supply and ES8000 exit device.

1

08102710    05/07

(ES5000 MANUFACTURED AFTER 5/06)

ES9000 SERIES

PS501 
POWER SUPPLY

TURN OFF 120 VAC POWER BEFORE

MAKING ANY CONNECTIONS OR SERVICE.

ED800 

TRANSFER

POWER 

ES-105

Содержание ED800 J

Страница 1: ...DORMA ED800 SERIES 08102710 05 07 www dorma usa com 1 800 523 8483 ED800 T ED800 J INSTALLATION INSTRUCTIONS...

Страница 2: ...itch Option 15 Fire Door Wiring 15 Power Adjustments Push Pull Switch 16 Latch Delay On Off Switch 16 Low Energy Function 16 Power Assist Function 17 Latched Door 17 ED800 Controller Module Diagram 18...

Страница 3: ...ors and accessories 1 Long No 2 Phillips screwdriver 2 No 3 Phillips screwdriver 3 1 8 blade screwdriver 4 3 16 blade screwdriver 5 Tape measure 6 10 Adjustable wrench 7 Center punch 8 Hammer 9 5mm He...

Страница 4: ...delay commences once there is no longer any door movement In the closing cycle a maximum of 15 lbf may be generated at the latch edge of the door If an obstacle is encountered the unit will balance th...

Страница 5: ...an obstacle within the swing area of the door In addition the unit will hold the door in the fully opened position until traffic has cleared from the swing area of the door Under no circumstances how...

Страница 6: ...ME FOR PLATE FOR 1 4 20 MACHINE SCREWS USE No 7 0 201 DRILL FOR No 14 WOOD SCREWS USE 5 32 DRILL FOR SEX NUTS USE 3 8 DRILL TWO 2 HOLES IN DOOR FOR ARM SHOE 8 13 16 1 3 4 SEE NOTE 5 2 TO 6 STD 3 1 4 8...

Страница 7: ...ew in connecting arm so arm slides freely Adjust connecting arm length so rod and connecting arm are 90 to door Re tighten screw 08102710 05 07 ED800 7 Initially install screws for slots A as pictured...

Страница 8: ...2 HOLES IN DOOR FOR ARM SHOE 8 13 16 1 3 4 SEE NOTE 5 2 TO 6 STD 3 1 4 83 3 15 16 100 7 8 DIA HOLE FOR WIRE ACCESS 15 16 MINIMUM TO CEILING 1 3 4 1 5 16 33 12 5 8 321 525 20 11 16 4 3 8 111 11 16 17 6...

Страница 9: ...Tighten all screws securely 08102710 05 07 Remove two 2 cover screws and cover Disconnect cover ground wire at base plate Loosen but do not remove end cap screws and slide end caps off Note Re instal...

Страница 10: ...oe drop plate Place wrench on top pinion shaft and rotate pinion slightly toward latch edge of door Slide main arm over bottom pinion shaft Fasten securely with pinion screw and lock washer provided L...

Страница 11: ...ed COVER END CAP END CAP WITH SWITCHES GROUND WIRE FOR COVER END CAP SCREW LEFT HAND MOUNT SHOWN 100 1 2 597 13 21 13 16 3 RIGHT HAND DOOR SHOWN BOTTOM OF FRAME NOTES C OF HINGE 1 DO NOT SCALE DRAWING...

Страница 12: ...ided 08102710 05 07 ED800 12 Initially install screws for slots A as pictured allowing 5 16 between the screw head and the frame Align the slots in the mounting plate with the screws Slide the mountin...

Страница 13: ...JUSTMENT Adjust spring tension according to the chart below The ED 800 is shipped from the factory as a size 3 The spring power can be increased to a size 5 Clockwise turns increase spring power Do no...

Страница 14: ...power cord to the receptacle do not run through doorways window openings walls ceilings floors or the like Do not attach or otherwise secure the power cord to the building structure and do not conceal...

Страница 15: ...nce to The National Electrical Code FUSE The ED 800 is protected by a 3 amp type AGC size 1 4 x 1 1 4 fuse Replace only with an identical fuse WARNING DISCONNECT POWER TO THE ED 800 WHEN REPLACING THE...

Страница 16: ...when the door is in the hold open position 5 Adjust the Delay Time potentiometer to obtain the desired amount of time the door will remain at the hold open position This is adjustable from 5 to 60 se...

Страница 17: ...le holding the latch retracted until the learn cycle is completed POWER ASSIST FUNCTION 1 Adjust the Power Assist Low Energy slide switch to the Power Assist position 2 Adjust the Door Width potentiom...

Страница 18: ...use only Hold Open Switch Connection Closing Obstacle Switch Off On Mount Style Switch Push Pull Latch Delay Switch Off On External Connector NOTE Terminal can be removed from control module to simpl...

Страница 19: ...external connector Note Accessory wires must be isolated from 120V incoming power ACCESSORY WIRE ROUTING Remove knockout with a 1 2 diameter punch and hammer Back side of end cap must be supported to...

Страница 20: ...allow for the door to open FS 1 FRAME SWITCH The FS 1 Frame Switch is designed to be installed in a metal door frame with a minimum width of 1 3 4 NOTE Generally a junction box is not used with this t...

Страница 21: ...hes numbered 1 through 10 located on the receiver board To gain access to the switch remove the top section of the case Any combination of on closed or off open positions can be selected by using a sm...

Страница 22: ...s weak or dead and should be replaced After installation is complete check for proper operation KC RFT 1 Transmitter and KC RFT 2 Transmitter The KC RFT key chain transmitters are used in conjunction...

Страница 23: ...cause both doors to open at the same time ED800 23 08102710 05 07 SEQUENTIAL OPERATION SINGLE DOORS In this operation the doors will open in sequence The switch at each door will activate that door Af...

Страница 24: ...0 provides a normally open set of contacts which close momentarily to act as a switch to signal the power supply for the latch retraction When activated the contacts close immediately and stay closed...

Страница 25: ...A ADJUSTMENT DELAY FIRE 1 2 CONTACT DRY 3 4 5 INPUT OUTPUT B 120 VAC DIP SWITCH OUTPUT A 8 DRY CONTACT 6 7 OFF ON INPUT POWER TRANSFER EXIT DEVICE Typical wiring diagram for the ED800 with PS501 Power...

Страница 26: ......

Страница 27: ...02710 05 07 ED800 27 ED 800J x 870 ANGLE BRACKET TOP JAMB INSTALLATION TEMPLATE ED 800J x 870 ANGLE BRACKET x 831 ARM SHOE DROP PLATE TOP JAMB INSTALLATION TEMPLATE 1 1 4 44 32 3 LEFT HAND DOOR SHOWN...

Страница 28: ...smitter Type Frequency Range Numbers of Codes Battery Type ED800 28 08102710 05 07 120 Volts AC 10 15 50 60 Hz 2 Amp 3 Amp type AGC size 1 4 x 1 1 4 12 Volts nominal filtered unregulated Range 10 to 2...