ELECTRICAL SPECIFICATIONS
ED 800
Power Requirements:
Current:
Fuse:
Auxiliary Power Output:
Max.Strike Switch Rating:
WS-1 Wall Switch
Switch Type:
Switch Rating:
FS-1 Wall Switch
Switch Type:
Switch Rating:
RFR Radio Frequency Receiver
Frequency:
Supply Voltage:
Power Consumption (rest):
Power Consumption (relay on)
Relay Contact Rating:
Numbers of Codes:
WS/RFT-1 Wall Switch
Switch Type:
Switch Rating:
Frequency:
Range:
Numbers of Codes:
Battery Type:
HH/RFT-1, HH/RFT-2 Transmitter
Transmitter Type:
Frequency:
Range:
Numbers of Codes:
Battery Type:
KC/RFT-1, KC/RFT-2 Transmitter
Transmitter Type:
Frequency:
Range:
Numbers of Codes:
Battery Type:
ED800-28
08102710 05/07
120 Volts AC +10 -15%, 50/60 Hz
2 Amp
3 Amp - type AGC - size 1/4" x 1 1/4"
12 Volts (nominal) filtered unregulated
Range 10 to 25 Volts DC @ 500mA
48 VAC/DC @ 1 Amp Max.(terminals 6,7, 8)
SPDT
15 Amp @ 125 or 250 Volts AC
SPDT
15 Amp @ 125 or 250 Volts AC
300 MHz std. or 310 MHz jumper selectable
12 - 30 Volts AC/DC
16mA
50mA
30 Volts AC/DC @ 5 Amp Max.
1024
SPDT
15 Amp @ 125 or 250 Volts
300 MHz
Normally 50 ft. - depending on local conditions
1024
9 Volt NEDA 1604 (Eveready 216 or equivalent)
Hand held
300 MHz
Normally 50 ft. - depending on local conditions
1024
9 Volt NEDA 1604 (Eveready 216 or equivalent)
Key chain
300 MHz
Normally 50 ft. - depending on local conditions
1024
12 Volt (Eveready A23 or equivalent)
Содержание ED800 J