background image

ELECTRICAL SPECIFICATIONS

ED 800
Power Requirements:  
Current:                                
Fuse:                                        
Auxiliary Power Output:              
                                                   
Max.Strike Switch Rating:              

WS-1 Wall Switch
Switch Type:                              
Switch Rating:                              

FS-1 Wall Switch
Switch Type:                              
Switch Rating:                       

RFR Radio Frequency Receiver
Frequency:              
Supply Voltage:               
Power Consumption (rest):      
Power Consumption (relay on)  
Relay Contact Rating:           
Numbers of Codes:               

WS/RFT-1 Wall Switch
Switch Type:                     
Switch Rating:                     
Frequency:                      
Range:                                      
Numbers of Codes:               
Battery Type:                       

HH/RFT-1, HH/RFT-2 Transmitter
Transmitter Type:                     
Frequency:                             
Range:                              
Numbers of Codes:                     
Battery Type:                               

KC/RFT-1, KC/RFT-2 Transmitter
Transmitter Type:                      
Frequency:                
Range:                               
Numbers of Codes:                      
Battery Type:                       

ED800-28

08102710    05/07

 

120 Volts AC   +10 -15%,   50/60 Hz
2 Amp
3 Amp - type AGC - size 1/4" x 1 1/4"
12 Volts (nominal) filtered unregulated
Range 10 to 25 Volts DC @ 500mA
48 VAC/DC @ 1 Amp Max.(terminals 6,7, 8)

SPDT
15 Amp @ 125 or 250 Volts AC

 
SPDT
15 Amp @ 125 or 250 Volts AC

 
300 MHz std. or 310 MHz jumper selectable
12 - 30 Volts AC/DC
16mA
50mA
30 Volts AC/DC @ 5 Amp Max.
1024

 
SPDT
15 Amp @ 125 or 250 Volts
300 MHz
Normally 50 ft. - depending on local conditions
1024
9 Volt NEDA 1604 (Eveready 216 or equivalent)

Hand held
300 MHz
Normally 50 ft. - depending on local conditions
1024
9 Volt NEDA 1604 (Eveready 216 or equivalent)

 
Key chain
300 MHz
Normally 50 ft. - depending on local conditions
1024
12 Volt (Eveready  A23 or equivalent)

Содержание ED800 J

Страница 1: ...DORMA ED800 SERIES 08102710 05 07 www dorma usa com 1 800 523 8483 ED800 T ED800 J INSTALLATION INSTRUCTIONS...

Страница 2: ...itch Option 15 Fire Door Wiring 15 Power Adjustments Push Pull Switch 16 Latch Delay On Off Switch 16 Low Energy Function 16 Power Assist Function 17 Latched Door 17 ED800 Controller Module Diagram 18...

Страница 3: ...ors and accessories 1 Long No 2 Phillips screwdriver 2 No 3 Phillips screwdriver 3 1 8 blade screwdriver 4 3 16 blade screwdriver 5 Tape measure 6 10 Adjustable wrench 7 Center punch 8 Hammer 9 5mm He...

Страница 4: ...delay commences once there is no longer any door movement In the closing cycle a maximum of 15 lbf may be generated at the latch edge of the door If an obstacle is encountered the unit will balance th...

Страница 5: ...an obstacle within the swing area of the door In addition the unit will hold the door in the fully opened position until traffic has cleared from the swing area of the door Under no circumstances how...

Страница 6: ...ME FOR PLATE FOR 1 4 20 MACHINE SCREWS USE No 7 0 201 DRILL FOR No 14 WOOD SCREWS USE 5 32 DRILL FOR SEX NUTS USE 3 8 DRILL TWO 2 HOLES IN DOOR FOR ARM SHOE 8 13 16 1 3 4 SEE NOTE 5 2 TO 6 STD 3 1 4 8...

Страница 7: ...ew in connecting arm so arm slides freely Adjust connecting arm length so rod and connecting arm are 90 to door Re tighten screw 08102710 05 07 ED800 7 Initially install screws for slots A as pictured...

Страница 8: ...2 HOLES IN DOOR FOR ARM SHOE 8 13 16 1 3 4 SEE NOTE 5 2 TO 6 STD 3 1 4 83 3 15 16 100 7 8 DIA HOLE FOR WIRE ACCESS 15 16 MINIMUM TO CEILING 1 3 4 1 5 16 33 12 5 8 321 525 20 11 16 4 3 8 111 11 16 17 6...

Страница 9: ...Tighten all screws securely 08102710 05 07 Remove two 2 cover screws and cover Disconnect cover ground wire at base plate Loosen but do not remove end cap screws and slide end caps off Note Re instal...

Страница 10: ...oe drop plate Place wrench on top pinion shaft and rotate pinion slightly toward latch edge of door Slide main arm over bottom pinion shaft Fasten securely with pinion screw and lock washer provided L...

Страница 11: ...ed COVER END CAP END CAP WITH SWITCHES GROUND WIRE FOR COVER END CAP SCREW LEFT HAND MOUNT SHOWN 100 1 2 597 13 21 13 16 3 RIGHT HAND DOOR SHOWN BOTTOM OF FRAME NOTES C OF HINGE 1 DO NOT SCALE DRAWING...

Страница 12: ...ided 08102710 05 07 ED800 12 Initially install screws for slots A as pictured allowing 5 16 between the screw head and the frame Align the slots in the mounting plate with the screws Slide the mountin...

Страница 13: ...JUSTMENT Adjust spring tension according to the chart below The ED 800 is shipped from the factory as a size 3 The spring power can be increased to a size 5 Clockwise turns increase spring power Do no...

Страница 14: ...power cord to the receptacle do not run through doorways window openings walls ceilings floors or the like Do not attach or otherwise secure the power cord to the building structure and do not conceal...

Страница 15: ...nce to The National Electrical Code FUSE The ED 800 is protected by a 3 amp type AGC size 1 4 x 1 1 4 fuse Replace only with an identical fuse WARNING DISCONNECT POWER TO THE ED 800 WHEN REPLACING THE...

Страница 16: ...when the door is in the hold open position 5 Adjust the Delay Time potentiometer to obtain the desired amount of time the door will remain at the hold open position This is adjustable from 5 to 60 se...

Страница 17: ...le holding the latch retracted until the learn cycle is completed POWER ASSIST FUNCTION 1 Adjust the Power Assist Low Energy slide switch to the Power Assist position 2 Adjust the Door Width potentiom...

Страница 18: ...use only Hold Open Switch Connection Closing Obstacle Switch Off On Mount Style Switch Push Pull Latch Delay Switch Off On External Connector NOTE Terminal can be removed from control module to simpl...

Страница 19: ...external connector Note Accessory wires must be isolated from 120V incoming power ACCESSORY WIRE ROUTING Remove knockout with a 1 2 diameter punch and hammer Back side of end cap must be supported to...

Страница 20: ...allow for the door to open FS 1 FRAME SWITCH The FS 1 Frame Switch is designed to be installed in a metal door frame with a minimum width of 1 3 4 NOTE Generally a junction box is not used with this t...

Страница 21: ...hes numbered 1 through 10 located on the receiver board To gain access to the switch remove the top section of the case Any combination of on closed or off open positions can be selected by using a sm...

Страница 22: ...s weak or dead and should be replaced After installation is complete check for proper operation KC RFT 1 Transmitter and KC RFT 2 Transmitter The KC RFT key chain transmitters are used in conjunction...

Страница 23: ...cause both doors to open at the same time ED800 23 08102710 05 07 SEQUENTIAL OPERATION SINGLE DOORS In this operation the doors will open in sequence The switch at each door will activate that door Af...

Страница 24: ...0 provides a normally open set of contacts which close momentarily to act as a switch to signal the power supply for the latch retraction When activated the contacts close immediately and stay closed...

Страница 25: ...A ADJUSTMENT DELAY FIRE 1 2 CONTACT DRY 3 4 5 INPUT OUTPUT B 120 VAC DIP SWITCH OUTPUT A 8 DRY CONTACT 6 7 OFF ON INPUT POWER TRANSFER EXIT DEVICE Typical wiring diagram for the ED800 with PS501 Power...

Страница 26: ......

Страница 27: ...02710 05 07 ED800 27 ED 800J x 870 ANGLE BRACKET TOP JAMB INSTALLATION TEMPLATE ED 800J x 870 ANGLE BRACKET x 831 ARM SHOE DROP PLATE TOP JAMB INSTALLATION TEMPLATE 1 1 4 44 32 3 LEFT HAND DOOR SHOWN...

Страница 28: ...smitter Type Frequency Range Numbers of Codes Battery Type ED800 28 08102710 05 07 120 Volts AC 10 15 50 60 Hz 2 Amp 3 Amp type AGC size 1 4 x 1 1 4 12 Volts nominal filtered unregulated Range 10 to 2...

Отзывы: