Dorma ED 100 Скачать руководство пользователя страница 7

ED 100, ED 250

7

8.  EC Declaration of conformity

DORMA Deutschland GmbH 

DORMA Platz 1, 58256 Ennepetal

hereby declares that the products  

ED 100, ED 250  

comply with the provisions of the named EC Directive(s) and 

that the standards and/or technical specifications referred to 

in the following have been applied.

Directive:

 

2006/95/EC 

Low Voltage Directive 

2004/108/EC Electromagnetic 

 

 compatibility

The technical documentation is available from the Product 

Compliance Manager: 

[email protected]

.

Harmonized European standard, national rule:

EN 13849-1 

EN ISO 12100-1 

EN ISO 14121-1 

BGR 232 

EN 61000 - 6 - 2 

EN 61000 - 6 - 3 

EN 61000 - 3 - 2  EN 61000 - 3 - 3 

EN 55022 

EN 60335 - 1 

EN 60950 - 1

9.  EC Declaration of incorporation

DORMA Deutschland GmbH 

DORMA Platz 1, 58256 Ennepetal

hereby declares that the incomplete machine 

ED 100, ED 250  

complies with the following basic requirements of the 

Machine Directive (2006/42/EC)- Appendix I, Article: 

1.1.3, 1.1.5, 1.2.1, 1.2.3, 1.2.5, 1.2.6, 1.3.1, 1.3.2, 1.3.3, 

1.3.4, 1.3.7, 1.3.8.1, 1.3.9, 1.5.1, 1.5.2, 1.5.4- 1.5.10, 

1.5.16, 1.6.1, 1.6.2, 1.6.3, 1.6.4, 1.7.1.1, 1.7.3, 1.7.4

The incomplete machine also complies with all relevant 

provisions of the directives 2006/95/EC und 2004/108/EC. 

It may be installed and operated in automatic door 

systems in accordance with the Machine Directive if the 

manufacturer of the system ensures that all requirements 

of the Machine Directive are complied with and if the 

manufacturer issues a EC Declaration of conformity.

The special technical documents have been prepared and 

are available from the Product Compliance Manager:  

[email protected]

Upon a substantiated request, they will be electronically 

transmitted to the national authorities.

6. Troubleshooting

Functional errors may have many causes.

The errors are often caused by environmental conditions and 

the drive unit will therefore try to detect and to react to them 

accordingly. The drive unit stops the current function and 

starts again after a waiting period or a new pulse. If it does 

not work, the automatic function will be shut off and an error 

message will be output. 

This is indicated by a red LED on the program switch.

The display flashes or lights permanently and indicates an 

error that need to be eliminated by the DORMA Service.

The following options are available to reset error messages:

1. 

Switch the program switch to the OFF position.

2. 

Mains reset. Switch off the power switch.  

Restart after 10 seconds.

The cause should be analyzed and eliminated before an error 

message is acknowledged.

Self-help in case of errors

In case errors occur during the operation  

please check the following: 

 

• Mains voltage available?

 

• Is the power switch on?

 

• Can the door be freely moved?

 

• Is the door manually locked, shutdown  

(lock switch) activated?

 

• Has the correct function been selected with the 

program switch?

 

• Is the turning range of the door free from obstacles?

 

• Has the hold-open system been triggered?

Please contact the Service Department if these points are 

okay and the doors system still does not work.

7.  Disassembly, recycling and disposal

The disassembly is carried out in the reverse order of the 

installation manual and must be carried out by qualified 

personnel.

 

De-energize the door system before disassembling the 

door system.

Dispose the product in an environmentally friendly 

manner. Electronic parts and batteries may not be 

disposed via the general trash.  

Take them to an appropriate collection point for 

disposal.

Always comply with the applicable national legal provisions.

Содержание ED 100

Страница 1: ...Operating instructions ED 100 ED 250...

Страница 2: ...remote controls out of the reach of children Never insert a metal object into the openings of the door system Otherwise there will be the risk of an electrical shock Content Page 1 General 2 2 Safety...

Страница 3: ...the door hinge side the internal program switch is always on the side of the main closing edge Power switch Internal program switch Power switch Internal program switch Program switch Use the program...

Страница 4: ...interval display If the internal 4 digit program switch is used a service interval display will be available A yellow LED will inform you about required maintenance work The service counters can be se...

Страница 5: ...display mounted on the outside changes to green and the display on the inside ceases Emergency opening from the outside In case of emergency situations the connection of an emergency button is provide...

Страница 6: ...risk of an electrical shock Clean the drive with a moist cloth and common cleaning agents Do not use any scrubbing agents as they might damage the surface Do not start the device before the surfaces a...

Страница 7: ...ctronically transmitted to the national authorities 6 Troubleshooting Functional errors may have many causes The errors are often caused by environmental conditions and the drive unit will therefore t...

Страница 8: ...WN 058176 45532 02 17 Subject to change without notice dormakaba Deutschland GmbH DORMA Platz 1 58256 ENNEPETAL DEUTSCHLAND Tel 49 2333 793 0 Fax 49 2333 793 4950 www dormakaba com...

Отзывы: