Dorma ED 100 Скачать руководство пользователя страница 5

ED 100, ED 250

5

3.10 Use on a barrier-free WC
Access to a barrier-free WC

If the status display mounted to the outside is green, the WC 

is vacant.

If you press the pushbutton mounted on the outside, the 

following will happen:

 

The door opens automatically.

 

The WC can now be entered.

 

The door closes once the set hold-open time has 

expired.

If you press the pushbutton mounted on the inside after the 

door is closed, the following will happen:

 

The pushbutton on the outside is deactivated.

 

The status display mounted on the outside lights red 

in order to signal "occupied“. 

 

The display mounted on the inside lights red to confirm 

to the user that the door is locked.

Leaving the barrier-free WC

If you press the pushbutton mounted on the inside, the 

following will happen:

 

The door opens automatically once the set hold-open 

time has expired.

 

A forced flushing may take place at the same time. 

 

If the door is closed again, the status display mounted 

on the outside changes to green and the display on the 

inside ceases.

Emergency opening from the outside

In case of emergency situations, the connection of an 

emergency button is provided. If activated, the guard locking 

is released and the door can only be opened manually. The 

automatic drive function will be shut off.

Alternatively, you can also open the door with a key from the 

outside in case of an emergency. In both cases, the outer 

status display will change from red to green and the inner 

display will cease. 

3.11 Accessories

In addition to an extensive range of DORMA accessories, 

many activators, locking devices, safety sensors and further 

accessories of other manufacturers are available that could 

be operated with the operators ED 100 and ED 250. 

Should the accessories not be part of the scope of delivery 

of DORMA, then DORMA cannot guarantee the compatibility. 

If these devices are used anyways, the full functional range 

of the drive may not be available or the device may not 

function properly. The drive unit or the connected device 

may also become damaged and the warranty might become 

void.

Содержание ED 100

Страница 1: ...Operating instructions ED 100 ED 250...

Страница 2: ...remote controls out of the reach of children Never insert a metal object into the openings of the door system Otherwise there will be the risk of an electrical shock Content Page 1 General 2 2 Safety...

Страница 3: ...the door hinge side the internal program switch is always on the side of the main closing edge Power switch Internal program switch Power switch Internal program switch Program switch Use the program...

Страница 4: ...interval display If the internal 4 digit program switch is used a service interval display will be available A yellow LED will inform you about required maintenance work The service counters can be se...

Страница 5: ...display mounted on the outside changes to green and the display on the inside ceases Emergency opening from the outside In case of emergency situations the connection of an emergency button is provide...

Страница 6: ...risk of an electrical shock Clean the drive with a moist cloth and common cleaning agents Do not use any scrubbing agents as they might damage the surface Do not start the device before the surfaces a...

Страница 7: ...ctronically transmitted to the national authorities 6 Troubleshooting Functional errors may have many causes The errors are often caused by environmental conditions and the drive unit will therefore t...

Страница 8: ...WN 058176 45532 02 17 Subject to change without notice dormakaba Deutschland GmbH DORMA Platz 1 58256 ENNEPETAL DEUTSCHLAND Tel 49 2333 793 0 Fax 49 2333 793 4950 www dormakaba com...

Отзывы: