Installation
28
Instruction manual DR-LA
3
is
5. Place the draught diverter in the support bracket and mark the centres for
the two drill holes on the top surface of the water heater. Remove the
draught diverter from the water heater.
6. Now drill two holes
into the top of the water heater (3.2 mm drill).
7. Place the sealing ring
8. Screw the draught diverter tightly in place.
9. Fit:
-
a 45° bend
onto the outlet of the draught diverter, followed by:
-
a corrosion-resistant vertical chimney pipe
of at least 0.5 metre,
-
the remaining flue components.
n
Caution
Use flue gas discharge materials that comply with the regulations. See
paragraph
.
n
Caution
Make sure that the chimney discharges into an area where this is permitted
for this category of water heater.
3.9.3
Flue gas thermostat assembly
Attached to the control column is a plastic bag containing the flue gas
thermostat with sensor and related attachment materials. The cable from the
sensor is already connected in the control column. The thermostat/bracket and
sensor have yet to be fitted inside the draught diverter. See
.
Warning
If the flue gas thermostat is not (or is incorrectly) fitted/connected, the flue
gas discharge will not be protected. An incorrectly fitted chimney can cause
flue gases to backflow into the boiler room.
Fit the flue gas thermostat as follows:
1. Take the bracket
1
with thermostat and sensor
2
from the packaging.
2. Place the bracket in the draught diverter and screw the bracket and the
sensor firmly in place.
3. Bend the cable clips
3
around the cable
4
of the flue gas thermostat.
Figure 3.6
Flue gas thermostat assembly
1
3
4
2
IMD-0137.
2
Содержание DR-LA 110
Страница 2: ...2...
Страница 6: ...6 Instruction manual DR LA gis...
Страница 16: ...Functioning of the water heater 16 Instruction manual DR LA 2 gis...
Страница 42: ...Filling and draining 42 Instruction manual DR LA 4 gis...
Страница 46: ...Controls 46 Instruction manual DR LA 5 gis...
Страница 64: ...Appendices 64 Instruction manual DR LA A is...