![DORCHESTER DR-FC 120 Скачать руководство пользователя страница 73](http://html1.mh-extra.com/html/dorchester/dr-fc-120/dr-fc-120_installation-comissioning-and-maintenance-instructions_2521679073.webp)
is
Instruction manual DR-FC
71
Water leakage
Leakage from a water
connection (threaded)
Tighten the threaded connection
If the leak persists, consult your installation engineer
Condensate leakage
Check that the condensation water discharge is working properly.
Rectify if necessary
Leakage from another
nearby water water
heater or pipe segment
Trace the leak
Leakage from the water
heater tank
Consult the supplier and/or manufacturer
Explosive ignition
Incorrect supply
pressure and/or CO
2
Set
(3.11 "Checking supply pressure, CO
2
value and switching
pressure")
the correct supply pressure and/or CO
2
.
If ignition is not improved, consult your installation engineer.
Contaminated burner
Clean the burner
(15.4.2 "Clean burner")
Insufficient or no hot
water
The water heater is off Start the water heater
(9 "Starting the water heater")
No supply voltage
present
1. Check whether the isolator is ON.
2. Check that there is power to the isolator.
3. Check whether the ON/OFF switch of the controller is ON
(position I).
4. Check whether there is power to the electrical connector block.
5. The measured voltage must be 230 V
AC
(-15%, +10%)
See the electrical diagram
(17 "Appendices")
.
If the error persists, consult your installation engineer.
Hot water supply is
used up
Reduce hot water consumption and give the water heater time to
heat up.
If there continues to be insufficient or no hot water, consult your
installation engineer.
The controller is in the
OFF position.
Switch the controller to the ON position
(11.3 "Switching to "ON
mode"")
.
Temperature (T
set
) is
set too low.
Set temperature (T
set
) to a higher setting
(11.4 "Setting the water
temperature")
.
Indication
Cause
Measure
Remark
Содержание DR-FC 120
Страница 2: ......
Страница 4: ......
Страница 6: ...4 Instruction manual DR FC gis...
Страница 10: ...Table of contents 8 Instruction manual DR FC...
Страница 30: ...Installation 28 Instruction manual DR FC 3 is Installation types IMD 0790 R0 C43 C13 C53 B23 C33...
Страница 58: ...Shutting down 56 Instruction manual DR FC 10 gis...
Страница 70: ...Service program 68 Instruction manual DR FC 12 is...
Страница 84: ...Service interval 82 Instruction manual DR FC 14 is...
Страница 89: ...Instruction manual DR FC 87 s 16 Warranty Contact your supplier for the warranty conditons of this water heater...
Страница 90: ...Warranty 88 Instruction manual DR FC 16 s...
Страница 93: ...Instruction manual DR FC 91 is...
Страница 96: ...Appendices 94 Instruction manual DR FC 17 is...
Страница 98: ...Instruction manual DR FC 96...