12.4 Displaying the water heater history
The water heater history sub-menu is used to display
the burning hours, the number of ignitions, the number
of flame errors and the number of ignition errors.
Call up the menu for displaying the water heater
history as follows:
•
:
APPLIANCE HISTORY
The figure shows an example.
12.5 Display the selected water heater
Call up the menu for displaying the water heater
selection as follows:
•
:
SELECT APPLIANCE
The water heater number can be found on the
rating plate.
The water heater selection has been correctly
preset in the factory.
12.6 Switching the pump on or off
If a program-controlled pump is
installed
(3.10.5 "Connecting a program-controlled
pump")
, it can be switched ON or OFF as follows:
•
:
PUMP RELAY
The standard setting for the pump relay is OFF.
If the mode
WEEK PROGRAM
or
EXTRA PERIOD
is
active, then the setting for mode
WEEK PROGRAM
or
EXTRA PERIOD
has priority over the ON/OFF
selection for the pump relay in the service menu.
Example
One of the week program periods is currently active.
During this period, the pump relay setting is OFF. If the
pump relay is set ON in the service menu, the pump
will nonetheless remain OFF. The pump will only
switch ON once the week program period has ended.
12.7 Setting the service interval
See Errata.
interval
(14.2 "Determining service interval")
which
defines the frequency of maintenance by the service
and maintenance engineer based on the number of
burning hours.
The service interval is based on the number of burning
hours. This can be set to 500, 1000 and 1500 hours.
The standard setting for number of hours is
500
. Once
the preset number of hours is reached, an appropriate
message
(8.4 "Service condition")
will appear. Set the
service interval as follows:
•
:
SERVICE INTERVAL
12.8 Service mode
The Installation engineer uses the
SERVICE
OPERATION
menu to adjust the water heater CO
2
setting during
FULL LOAD
and
PARTIAL LOAD
operation.
Use :
SERVICE OPERATION
to display the
SERVICE OPERATION
menu.
and can be used to switch between
PARTIAL
LOAD
and
FULL LOAD
.
If there is a heat demand, the water heater will first run
through a startup cycle, then continue to operate in
FULL LOAD
or
PARTIAL LOAD
mode.
If there is no heat demand, the installation engineer
must create one. This can be done by draining the
water heater until it is cold or by temporarily raising the
set point using . After adjustment, the set point must
be set back to the original value using .
if you exit the
SERVICE OPERATION
menu or if no
buttons are pressed for a period of 15 minutes, the
water heater will revert to the original operating mode.
APPLIANCE HISTORY
BURNINGHOURS 000410
^IGNITIONS
001000
ÈFLAME ERRORS 000021
IGNIT ERROR
000013
SELECT APPLIANCE
»5934
^ 8576
È 3379
6527
....
PUMP RELAY
»ON
OFF
SERVICE INTERVAL
» 500
^ 1000 BURNING HOURS
È 1500
SERVICE OPERATION
»FULL LOAD
PARTIAL LOAD
Содержание DR-FC 120
Страница 2: ......
Страница 4: ......
Страница 6: ...4 Instruction manual DR FC gis...
Страница 10: ...Table of contents 8 Instruction manual DR FC...
Страница 30: ...Installation 28 Instruction manual DR FC 3 is Installation types IMD 0790 R0 C43 C13 C53 B23 C33...
Страница 58: ...Shutting down 56 Instruction manual DR FC 10 gis...
Страница 70: ...Service program 68 Instruction manual DR FC 12 is...
Страница 84: ...Service interval 82 Instruction manual DR FC 14 is...
Страница 89: ...Instruction manual DR FC 87 s 16 Warranty Contact your supplier for the warranty conditons of this water heater...
Страница 90: ...Warranty 88 Instruction manual DR FC 16 s...
Страница 93: ...Instruction manual DR FC 91 is...
Страница 96: ...Appendices 94 Instruction manual DR FC 17 is...
Страница 98: ...Instruction manual DR FC 96...