![DORCHESTER DR-FC 120 Скачать руководство пользователя страница 50](http://html1.mh-extra.com/html/dorchester/dr-fc-120/dr-fc-120_installation-comissioning-and-maintenance-instructions_2521679050.webp)
Draining
48
Instruction manual DR-FC
6
gis
6.1
Draining unvented
installations
Some service activities require the water heater to be drained. The procedure
is as follows:
1. Activate the
MENU
with
.
2. Position the cursor in front of
OFF
.
3. Confirm
OFF
with
.
4. Wait until the fan has stopped. The icon is then dimmed.
Caution
Failure to wait until the fan stops can cause damage to the water heater.
5. Switch the water heater OFF (position 0) using the ON/OFF switch on the
control panel.
6. Isolate the water heater from the power supply by setting the isolator
between the water heater and the mains power supply to position 0.
7. Shut off the gas supply (10).
8. Close the stop valve (11) in the hot water pipe.
9. Close the supply valve (4) in the cold water inlet (A).
10. Open the drain valve (9).
6.2
Draining vented
installations
Some service activities require the water heater to be drained. The procedure
is as follows:
1. Activate the
MENU
with
.
2. Position the cursor in front of
OFF
.
3. Confirm
OFF
with
.
4. Wait until the fan has stopped. The icon is then dimmed.
Caution
Failure to wait until the fan stops can cause damage to the water
heater.
5. Switch the water heater OFF (position 0) using the ON/OFF switch on the
control panel.
6. Isolate the water heater from the power supply by setting the isolator
between the water heater and the mains power supply to position 0.
7. Shut off the gas supply (10).
8. Close the stop valve (11) in the hot water pipe.
9. Close the stop valve (4) between the cold water head tank and the cold
water inlet (A).
10. Open the drain valve (9).
11. Bleed the water heater (or installation) so that it drains completely.
MENU
»OFF
^ ON
È WEEK PROGRAM
Содержание DR-FC 120
Страница 2: ......
Страница 4: ......
Страница 6: ...4 Instruction manual DR FC gis...
Страница 10: ...Table of contents 8 Instruction manual DR FC...
Страница 30: ...Installation 28 Instruction manual DR FC 3 is Installation types IMD 0790 R0 C43 C13 C53 B23 C33...
Страница 58: ...Shutting down 56 Instruction manual DR FC 10 gis...
Страница 70: ...Service program 68 Instruction manual DR FC 12 is...
Страница 84: ...Service interval 82 Instruction manual DR FC 14 is...
Страница 89: ...Instruction manual DR FC 87 s 16 Warranty Contact your supplier for the warranty conditons of this water heater...
Страница 90: ...Warranty 88 Instruction manual DR FC 16 s...
Страница 93: ...Instruction manual DR FC 91 is...
Страница 96: ...Appendices 94 Instruction manual DR FC 17 is...
Страница 98: ...Instruction manual DR FC 96...