Every 3000 Service Hours or 18 Months
You must read and understand the warnings and instructions contained in the Safety section of this manual,
before performing any operation or maintenance procedures.
Timing Belt - Change
See the “Service Manual” for the procedure and
specifications.
Timing Belt for Counterbalance
Shaft - Change
See the “Service Manual” for the procedure and
specifications.
Every 4500 Service Hours or two Years
Replace Oxygen Sensor
(1) Oxygen Sensor
1.
Stop engine and wait until the exhaust pipe and
exhaust pipe is cooled.
2.
Disconnect the electrical connector of oxygen
sensor
3.
Remove oxygen sensor
4.
Assemble new oxygen sensor
Tightening torque : 45 N•m (32.5 lb•ft)
5.
Connect the electrical connector of oxygen
sensor