Table 2. MI-07 Diagnostic Fault Codes (Flash Codes) cont’d.
DFC
PROBABLE FAULT
FAULT ACTION *
CORRECTIVE ACTION
FIRST CHECK
572
MediumOverspeed
Engine speed has exceeded
the second level (2 of 3) of
overspeed protection
(1) TurnOnMil
(2) MediumRevLimit
Usually associated with additional ETC
faults
Check for ETC Sticking or other ETC
faults
Verify if the lift truck was motored down
a steep grade
573
SoftOverspeed
Engine speed has exceeded
the first level (1 of 3) of
overspeed protection
(1) TurnOnMil
(2) SoftRevLimit
Usually associated with additional ETC
faults
Check for ETC Sticking or other ETC
faults
Verify if the lift truck was motored down
a steep grade
611
(61)
APP1RangeLow
APP1 sensor voltage out of
range low, normally set if the
APP1 signal has shorted to
ground, circuit has opened or
sensor has failed
(1) TurnOnMil
(2) CheckEngine Light
Check foot pedal connector
Check APP1 signal at SECM PIN B7
612
(65)
APP2RangeLow
APP2 sensor voltage out of
range low, normally set if the
APP2 signal has shorted to
ground, circuit has opened or
sensor has failed
TurnOnMil
Check foot pedal connector
Check APP2 signal at SECM PIN B16
621
(62)
APP1RangeHigh
APP1 sensor voltage out of
range high, normally set if
the APP1 signal has shorted
to power or the ground for
the sensor has opened
1) TurnOnMil
(2) CheckEngine Light
Check foot pedal connector
Check APP1 signal at SECM PIN B7
622
(66)
APP2RangeHigh
APP2 sensor voltage out of
range high, normally set if
the APP2 signal has shorted
to power or the ground for
the sensor has opened
TurnOnMil
Check foot pedal connector
Check APP2 signal at SECM PIN B16
631
(63)
APP1AdaptLoMin
Learned idle end of APP1
sensor range lower than
expected
None
Check APP connector and pins for
corrosion
Cycle the pedal several times and
check APP1 signal at SECM Pin B7
632
(67)
APP2AdaptLoMin
Learned idle end of APP2
sensor range lower than
expected
None
Check APP connector and pins for
corrosion
Cycle the pedal several times and
check APP2 signal at SECM Pin B16
641
(64)
APP1AdaptHiMax
Learned full pedal end of
APP1 sensor range higher
than expected
None N/A
642
(68)
APP2AdaptHiMax
Learned full pedal end of
APP2 sensor range higher
than expected
None N/A
(*) Fault actions shown are default values specified by the OEM.
https://www.forkliftpdfmanuals.com/
Содержание D35S-5
Страница 2: ...https www forkliftpdfmanuals com ...
Страница 31: ...Safety Section 29 Lean away from the direction of fall Lean forward https www forkliftpdfmanuals com ...
Страница 41: ...General Section 39 Capacity Chart D G 35S 5 D G 40S 5 D G 45S 5 https www forkliftpdfmanuals com ...
Страница 42: ...General Section 40 Capacity Chart D G 35S 5 D G 40S 5 D G 45S 5 https www forkliftpdfmanuals com ...
Страница 45: ...General Section 43 Capacity Chart D G 40SC 5 D G 45SC 5 D G 50SC 5 https www forkliftpdfmanuals com ...
Страница 46: ...General Section 44 Capacity Chart D G 40SC 5 D G 45SC 5 D G 50SC 5 https www forkliftpdfmanuals com ...
Страница 49: ...General Section 47 Capacity Chart D G 50C 2 D G 50C 5 https www forkliftpdfmanuals com ...
Страница 50: ...General Section 48 Capacity Chart with Side Shifter D G 50C 2 D G 50C 5 https www forkliftpdfmanuals com ...
Страница 196: ...https www forkliftpdfmanuals com ...
Страница 225: ...Safety Section 29 Lean away from the direction of fall Lean forward https www forkliftpdfmanuals com ...