Operation Section
-98-
Table 2. MI-07 Diagnostic Fault Codes (Flash Codes) cont’d.
DFC
PROBABLE FAULT
FAULT ACTION *
CORRECTIVE ACTION
FIRST CHECK
342
MAPRangeHigh
Manifold Absolute Pressure
Sensor Input is High,
normally set if the TMAP
pressure signal wire has
become shorted to power,
shorted to the IAT signal, the
TMAP has failed or the
SECM has failed
(1) TurnOnMil
(2) CutThrottle
Check TMAP connector and MAP
signal wiring for a shorted circuit
TMAP Pin 4 to SECM Pin B18 (signal)
TMAP Pin 1 to SECM Pin B1
(sensor GND)
TMAP Pin 3 to SECM Pin B24
(XDRP +5 Vdc)
Check the MAP sensor by
disconnecting the TMAP connector
and measuring at the sensor:
TMAP Pin 1(GND) to Pin 4 (pressure
signal KPA) (2.4k
Ω
- 8.2k
Ω
)
TMAP Pin 3 (power) to Pin 4 (pressure
signal KPA) (3.4k
Ω
- 8.2k
Ω
)
351
MAP_IR_HI
MAP sensor indicates higher
pressure than expected
None
Check for vacuum leaks. Check that
TMAP sensor is mounted properly.
Possible defective TMAP sensor.
352
MAP_IR_LO
MAP sensor indicates lower
pressure than expected
None
Possible defective TMAP sensor.
353
MAP_STICKING
MAP sensor not changing as
expected
None
Check that TMAP sensor is mounted
properly. Possible defective TMAP
sensor.
371
(37)
IATRangeLow
Intake Air Temperature
Sensor Input is Low normally
set if the IAT temperature
sensor wire has shorted to
chassis ground or the sensor
has failed.
TurnOnMil
Check TMAP connector and IAT signal
wiring for a shorted circuit
TMAP Pin 2 to SECM Pin B12 (signal)
TMAP Pin 1 to SECM Pin B1
(sensor GND)
To check the IAT sensor of the TMAP
disconnect the TMAP connector and
measure the IAT resistance
Resistance is approx 2400 ohms at
room temperature.
381
(38)
IATRangeHigh
Intake Air Temperature
Sensor Input is High
normally set if the IAT
temperature sensor wire has
been disconnected or the
circuit has opened to the
SECM.
TurnOnMil
Check TMAP connector and IAT signal
wiring for a shorted circuit
TMAP Pin 2 to SECM Pin B12 (signal)
TMAP Pin 1 to SECM Pin B1
(sensor GND)
To check the IAT sensor of the TMAP
disconnect the TMAP connector and
measure the IAT resistance
Resistance is approx 2400 ohms at
room temperature.
391
IAT_IR_Fault
Intake Air Temperature not
changing as expected
None
Check connections to TMAP sensor.
Check that TMAP sensor is properly
mounted to manifold.
(*) Fault actions shown are default values specified by the OEM.
https://www.forkliftpdfmanuals.com/
Содержание D35S-5
Страница 2: ...https www forkliftpdfmanuals com ...
Страница 31: ...Safety Section 29 Lean away from the direction of fall Lean forward https www forkliftpdfmanuals com ...
Страница 41: ...General Section 39 Capacity Chart D G 35S 5 D G 40S 5 D G 45S 5 https www forkliftpdfmanuals com ...
Страница 42: ...General Section 40 Capacity Chart D G 35S 5 D G 40S 5 D G 45S 5 https www forkliftpdfmanuals com ...
Страница 45: ...General Section 43 Capacity Chart D G 40SC 5 D G 45SC 5 D G 50SC 5 https www forkliftpdfmanuals com ...
Страница 46: ...General Section 44 Capacity Chart D G 40SC 5 D G 45SC 5 D G 50SC 5 https www forkliftpdfmanuals com ...
Страница 49: ...General Section 47 Capacity Chart D G 50C 2 D G 50C 5 https www forkliftpdfmanuals com ...
Страница 50: ...General Section 48 Capacity Chart with Side Shifter D G 50C 2 D G 50C 5 https www forkliftpdfmanuals com ...
Страница 196: ...https www forkliftpdfmanuals com ...
Страница 225: ...Safety Section 29 Lean away from the direction of fall Lean forward https www forkliftpdfmanuals com ...