1.3 Flush Mount

IMPORTANT:

 

Be sure to clean out the cabinet of 

any debris that can cause a short.
All necessary wiring should be connected to the 
14-pin terminal. See Section 1.4 Terminal Wiring.

Mount rough-in box into the pilaster, wall or 
kiosk. Run conduit inside wall into bottom of 
rough-in box if desired. Use appropriate 
hardware (Not supplied) to secure the rough-in 
box in place.

Mount in a Pilaster,

Wall or Kiosk

Bolt flush box into 
the rough-in box with 
4 supplied bolts.

See spec page in 
front of this manual 
for dimensions about 
your model.

Rough-In Box

Conduit
in W

all

Flush
Box

1.2 Surface Mount

Surface mount cabinet can be mounted directly to a 
wall or pilaster. They can be post mounted using a 
DoorKing mounting post (there are several different 
styles available). Be sure keypad is securely mounted 
and is not subject to continuous vibration from 
closing doors or gates.

Use existing 4 holes in surface 
mount cabinet box to bolt on a 
DoorKing mounting post.
Use the hardware that is
supplied with the
mounting post.

Note:

 A gooseneck 

mounting post 
anchored in concrete 
does not make a 
good ground.

Mount on a Post

Run ALL wires that will be 
needed during the cabinet 
installation and connect to 
14-pin terminal. See Section 
1.4 Terminal Wiring.

Use the 4 existing holes in 

the cabinet. Run conduit 

inside of wall or pilaster. Use 

appropriate hardware to 

mount the cabinet (Not 

supplied). Be sure that the 

mounting hardware 

does not 

protrude into the cabinet

 

where it could cause a short.

 Mount Directly

to a Wall or Pilaster

Plastic screw anchors 
for masonry if required.
(Not supplied)

1/2” Conduit

IMPORTANT:

 

Be sure to clean out the cabinet of any 

debris that can cause a short.
All necessary wiring should be connected to the 14-pin 
terminal. See Section 1.4 Terminal Wiring.

See spec page in front of 
this manual for dimensions 
about your model.

Содержание 1506-086

Страница 1: ...Stand Alone Digital Keypad Entry Devices Date Installed Installer Company Name Phone Number Leave Manual with Owner Circuit Board Serial Number and Revision Letter Model Number 1504 1504 1504 1506 150...

Страница 2: ......

Страница 3: ...ALL Four digit Entry Codes 2 7 Four digit Entry Code Divide Number 2 8 Programming Five digit Entry Codes 2 9 Erase a Five digit Entry Code 2 10 Erase ALL Five digit Entry Codes 2 11 Five digit Entry...

Страница 4: ...e rough in box Flush Box Flush Box Flush Box Push Button Push Button To Call To Call Push Button Push Button To Call To Call 1504 Surface Mount Dimensions P N 1504 086 10 5 25 6 125 2 5 2 5 1 125 Dia...

Страница 5: ...Box Flush Box Side Views Bottom Views Front Views Bolt holes 4 to secure flush box inside rough in box Flush Box Flush Box 1506 Surface Mount Dimensions P N 1506 086 Mounting Note Can be mounted on a...

Страница 6: ...ng diagrams in this manual Never mount this device to a moving gate or gate panel or next to a gate that causes vibration to the fence such as a spring loaded pedestrian gate Continuous vibration from...

Страница 7: ...is not subject to continuous vibration from closing doors or gates Use existing 4 holes in surface mount cabinet box to bolt on a DoorKing mounting post Use the hardware that is supplied with the moun...

Страница 8: ...te 12 24 VDC may also be used to power the 1504 1506 Note A low voltage power surge suppressor P N 1878 010 is recommended Power for electric strike or maglock is NOT provided by the 1504 1506 Use sep...

Страница 9: ...1504 Aiphone Intercom Station Connections Intercom Station 1504 AIPhone LEM Series 2 Wire System 3 Wire System E 1 Push to Call Button Speaker Blue Blue Red Red Capacitor 47uF 1504 Push to Call Butto...

Страница 10: ...1 4 M A S T E R C O D E O N 1 5 0 6 0 1 0 1 2 3 4 5 6 7 8 1 5 9 9 0 1 0 1 2 3 4 5 6 7 8 1 5 9 7 0 1 0 1599 Secondary Keypad Board 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1597 010 8 Conductor...

Страница 11: ...m in a new one but all other previously programmed information will remain intact The relay strike time sets the amount of time that the relay s will be activated when a valid entry code is entered on...

Страница 12: ...HAN the divide number will activate Relay 2 If NO divide number is programmed enter in step 2 then Relay 2 acts as an alarm by pass relay activating 1 second PRIOR to Relay 1 and deactivating 1 second...

Страница 13: ...s must be programmed to operate in the same mode If a divide number is programmed for the five digit codes then a divide number MUST also be programmed for the four digit entry codes see section 2 7 F...

Страница 14: ...R and UPPER boundaries for time ZONE 1 establishes a set of four digit entry codes that will be denied access if the time zone 1 input terminal 4 is activated Note This time zone does not affect the f...

Страница 15: ...can be programmed to operate either Relay 1 or Relay 2 When a five digit code is entered on the keypad the system checks its memory to see if the code is stored If the five digit entry code is not sto...

Страница 16: ...ate a relay that is latched simply re enter the number that was used to activate the relay See sample charts below Five digit entry codes are NOT affected by hold boundaries Relay 1 Relay 1 momentaril...

Страница 17: ...ime zone restricted Entry codes 3001 thru 3999 are not time zone restricted Entry codes 5001 and higher are not time zone restricted Time Zone 1 Entry codes 2000 thru 3000 are restricted by Time ZONE...

Страница 18: ...VA rating Relay hold feature may be activated Reprogram hold boundaries Section 2 12 Relay strike time may be programmed too long Reprogram Section 2 2 Request to exit input will not operate relay Ch...

Страница 19: ...ec Master Code section 2 1 Factory 9999 1st Digit 2nd Digit 3rd Digit 4th Digit Four digit Hold Boundaries section 2 12 Lower Upper Time ZONE 1 Boundaries section 2 13 Lower Upper Time ZONE 2 Boundari...

Страница 20: ...1506 065 K 6 17 18 NAME Four Digit Entry Code Make additional copies of this table as needed NAME Four Digit Entry Code Resident Four Digit Entry Codes...

Страница 21: ...1506 065 K 6 17 19 NAME Four Digit Entry Code Make additional copies of this table as needed NAME Four Digit Entry Code Resident Four Digit Entry Codes...

Страница 22: ...310 645 0023 Fax 310 641 1586 Installation Owner s Manual Models 1504 1506 Models 1504 1506 Models 1504 1506 Use this manual for circuit board 1506 010 Revision G or higher Programmable Stand Alone Di...

Отзывы: