1506-065-K-6-17
12
2.12 Hold Boundary Programming
1.
Press
*
0 7 and enter the MASTER CODE.
[
*
0 7 _ _ _ _ (beep)]
2.
Choose and enter a four-digit code for the
LOWER
hold boundary, then press
*
.
[ _ _ _ _
*
(beep)]
3.
Choose and enter a four-digit code for the
UPPER
hold boundary, then press
*
.
[ _ _ _ _
*
(beep)]
4.
Press 0 # TOGETHER to end.
[0 # (beeeeeep)]
The entry system hold boundaries establish a set of
four-digit entry codes
that will latch
Relay 1 ON
,
Relay 2 ON
, or
BOTH
Relay 1 and Relay 2 ON
(depending on the divide number programmed and the hold boundaries that have been programmed)
indefinitely. To un-latch the relay(s), a four-digit entry code within the hold boundary is entered on the keypad.
Factory setting is NO hold boundary programmed (# # # #).
Note:
Hold boundaries can only be established for the
four-digit entry codes
. Five-digit entry codes have no hold boundaries.
Note:
To delete existing hold boundaries, enter # # # # in steps 2 and 3.
Note:
See section 3.5 for examples.
Note:
See section 3.6 for examples.
Note:
See section 3.6 for examples.
2.13 Time ZONE 1 Boundary Programming
Programming the
LOWER
and
UPPER
boundaries for time
ZONE 1
establishes a set of four-digit entry codes that will be denied
access if the time zone 1 input (terminal 4) is activated.
Note:
This time zone does not affect the
five-digit entry codes
.
Factory setting is NO zone 1 boundary programmed (# # # #).
1.
Press
*
0 5 and enter the MASTER CODE.
[
*
0 5 _ _ _ _ (beep)]
2.
Choose and enter a four-digit code for the
LOWER
boundary, then press
*
.
[ _ _ _ _
*
(beep)]
3.
Choose and enter a four-digit code for the
UPPER
boundary, then press
*
.
[ _ _ _ _
*
(beep)]
4.
Press 0 # TOGETHER to end.
[0 # (beeeeeep)]
Note:
To delete existing time zone 1 boundaries, enter # # # # in steps 2 and 3.
2.14 Time ZONE 2 Boundary Programming
Programming the
LOWER
and
UPPER
boundaries for time
ZONE 2
establishes a set of four-digit entry codes that will be denied
access if the time zone 2 input (terminal 3) is activated.
Note:
This time zone does not affect the
five-digit entry codes
.
Factory setting is NO zone 2 boundary programmed (# # # #).
1.
Press
*
0 6 and enter the MASTER CODE.
[
*
0 6 _ _ _ _ (beep)]
2.
Choose and enter a four-digit code for the
LOWER
boundary, then press
*
.
[ _ _ _ _
*
(beep)]
3.
Choose and enter a four-digit code for the
UPPER
boundary, then press
*
.
[ _ _ _ _
*
(beep)]
4.
Press 0 # TOGETHER to end.
[0 # (beeeeeep)]
Note:
To delete existing time zone 2 boundaries, enter # # # # in steps 2 and 3.