11. Release operation

The electric operator SHAFT-120 is equipped with a manual chain reducer, which is used for emergency lifting/lowering of the gate in case of 
power cut. For emergency control, pull the red knob down up to the stop, avoiding in such way automatic actuation of the operator. To return 
to the automatic control, pull the green knob down up to the stop.

Important: It is forbidden to pull down the red knob, when the electric operator runs. That can cause damage of the motor.

Important: Intensive and continuous use of the manual chain reducer is forbidden. It may be used only in emergency.

Important: Before using the manual chain reducer, make sure, that the chain links are not deformed and are not dirty. Otherwise 
use of the reducer can cause its jamming.

If required, the door can be opened using the chain. Lengthen or shorten the chain so, that when  assembled, its edge is at a height of 50-150 
cm from the floor. It is recommended to fix the lower part of the chain, to avoid hindrance to people and equipment move. Besides attach the 
warning labels, showing closing and opening direction, so, that they can be easily seen.

RELEASE OPERATION

Secure the chain

Secure the knobs

Use  the  chain  only  in  case  of  emergency,  otherwise  the 
reducer parts can be damaged.

12.  MAINTENANCE

Make sure, that the gate operate properly and are balanced.

• 

Check operable condition of the system units and safety devices not less than once in six months.

• 

Have qualified technicians to service the operator.

• 

Keep the operator clean.

• 

The manufacturing company reserves the right to make changes in the products desribed in this manual and modify their design without 

notice and without obligation to notify any persons of any such revisions or changes.

The Manual describes installation and adjustment of the operator SHAFT-120.
Following the operator’s operating  and maintenance recommendations as well as operator’s and gate installation order, described in the 

manual will guaranty long life of the equipment and reduce the accidents at installation and operation of the gate.

Always observe safety standards at installation, operation and maintenance.
In the event you lost the Directions you may send a request letter for the duplicate copy to the following address: 
DoorHan, Russia, 143002, Moscow region,  Odintsovsky district, Akulovo village, Novaya street 120 or by e-mail: [email protected]
The producer (DoorHan) does not handle with installation of gates and automation, their maintenance and operation and shall no be held 

responsible for safety of installation, operation and maintenance of gates and automation.

The content of the Manual shall no be basis for any claim.

Содержание SHAFT-120

Страница 1: ...Installation and operating manual SHAFT 120 ...

Страница 2: ... components 8 7 Installation 9 7 1 On shaft mounting 9 7 2 Mounting via chain drive 10 8 Wiring 11 8 1 Control unit connection 12 9 Programming of operator 13 9 1 Selection of operational logic 13 10 Adjustment of close and open positions 13 10 1 Close position red cam 13 10 2 Open position blue cam 14 11 Release operation 16 12 Maintenance 17 13 Trouble shooting 18 14 Guaranty card 19 TABLE OF CO...

Страница 3: ...n release the operator by pulling the red knob and open the gate manually using the chain Important Check routinely the torsion spring adjustment when the springs are not adjusted properly the release can cause spontaneous closing of the door In an emergency case the door can be controlled manually through the chain Important Use the manual chain without the release only at emergency otherwise the...

Страница 4: ... gate Never let children play with the automatic system Deenergize the operator before putting it into operation after releasing or before removal its housing Do not go or drive through the gate during its closing or opening Do not impede moving of the gate Control of the gate shall be executed only under condition of its safe moving Do not pull the chain by hand to open or close the gate Ground p...

Страница 5: ...unting Mount the mounting bracket on the wall using screws The mounting bracket can be placed from the left or from the right of the operator Turn the release knob by 180 degrees counterclockwise Mount the first closing ring on the gate shaft Mount the operator on the gate shaft be sure that the bushing key is in its proper position and screw it to the mounting basis Mount the second closing ring ...

Страница 6: ...pply voltage terminal block X7 To select voltage 220V connect CO and 400V 2 Connection of supply voltage terminal block X5 Connect voltage 220V to terminals L1 L3 Connect voltage 380V to terminals L1 L2 L3 3 Motor terminal block X4 Connect motor to terminals U V and W 380V motor max operating current 9A wattage 4 kW 220V motor max operating current 2 4A wattage 2 4 kW 4 End switches terminal block...

Страница 7: ... not used install the jumper STOP and GND 220V Jumper for selection of supply voltage 380V Jumper for selection of supply voltage Fuse Transformer Jumpers Opening button Closing button External radio receiver Key switch 3 position control station Photocells Stop button Important If there are no safety devices install the jumper IR GND End switches Motor Black Brown Blue Supply voltage 3x380V 50 Hz...

Страница 8: ...lose and open the gate make sure that the blue cams push the micro switch and the indicator DL2 on the control unit is out Fine adjustment Turning the fine adjustment screw correct the closed position of the gate Clockwise turning of the screw causes earlier actuation of the end switch counter clockwise turning of the screw causes later actuation of the end switch Open and close the gate make sure...

Страница 9: ...only in case of emergency otherwise the reducer parts can be damaged 12 MAINTENANCE Make sure that the gate operate properly and are balanced Check operable condition of the system units and safety devices not less than once in six months Have qualified technicians to service the operator Keep the operator clean The manufacturing company reserves the right to make changes in the products desribed ...

Страница 10: ...n The door is not balanced Adjust the door Operator stops suddenly The operator s thermal protection works Let the operator cool Gate does not open completely or does not close completely Wrong adjustment of end switches Adjust end switches TROUBLE SHOOTING Bar code Component part Component part Component part Component part Component part Component part Component part Component part Serial number...

Страница 11: ...11 OPERATOR SHAFT 120 INSTALLATION AND OPERATING MANUAL notes ...

Страница 12: ... If you need any further information about purchasing distribution and maintenance contact our regional agents or our central office at the following address 120 Novaya street Akulovo village Odintsovo district Moskow region 143002 Russia Tel 7 495 933 2400 981 1133 E mail Info doorhan ru www doorhan ru ...

Отзывы: