2. GENERAL INFORMATION
The electromechanical operator SHAFT-120 of the company “DoorHan” is intended for automation of balanced industrial sectional
gates.
The electromechanical operator SHAFT-120 is a shaft-type operator with reduction gear in “oil bath”.
It consists of a mechanical reducer in “oil bath” and an electric motor with an integral control unit. The reducer and the motor have a
common housing.
A 3-position control station is connected to the control unit. The operator can be mounted either on the shaft or via the intermediate
chain-drive (optional).
The self-locking reducer enables mechanical lock of the gate shaft, when the motor does not work. In case of power disconnection the
emergency manual release with built-in hand chain drive enables manual opening or closing with chains.
2.1 BASIC FUNCTIONS
The automatic stop system enables quick and reliable stop of the motor in close and open positions.
In case of power cut you can release the operator by pulling the red knob and open the gate manually using the chain.
Important:
Check routinely the torsion spring adjustment: when the springs are not adjusted properly, the release can cause
spontaneous closing of the door.
In an emergency case the door can be controlled manually through the chain.
Important:
Use the manual chain without the release only at emergency, otherwise the chain reducer can fail.
Double end switches enable safe and reliable operation of the operator.
GENERAL INFORMATION
2.2 SPECIFICATIONS
Shaft-120
Power supply
~ 380V 50 Hz
Torque
120 Nm
Motor speed
1400 rpm
Shaft hole
25,4 mm with key way
Manual chain length
12 m
Shaft speed
22 rpm
Weight with chain
20 kg
Dimensions
430x290x120
Thermal protection
100
0
C
Intensity
60%
Oil amount
0,25 l
Engine power
370 W
Protection rating
IP44
Operation temperature
-40
0
C… +45
0
C
№
Name
Quantity
1
Operator
1
2
Bracket
1
3
Set of fastenings
1
4
Manual operator chain (12m)
1
5
External button switch
1
6
Manual
1
3. Delivery set
After receiving the operator, unpack it and make sure, that the operator is not damaged. If any damages are found, please contact
the supplier of the operator.
A standard package includes: