2. GENERAL INFORMATION

The  electromechanical  operator  SHAFT-120  of  the  company  “DoorHan”  is  intended  for  automation  of  balanced  industrial  sectional  

gates.

The electromechanical operator SHAFT-120 is a shaft-type operator with reduction gear in “oil bath”.
It consists of a mechanical reducer in “oil bath” and an electric motor with an integral control unit. The reducer and the motor have a 

common housing.

A 3-position control station is connected to the control unit. The operator can be mounted either on the shaft or via the intermediate 

chain-drive (optional).

The self-locking reducer enables mechanical lock of the gate shaft, when the motor does not work. In case of power disconnection the 

emergency manual release with built-in hand chain drive enables manual opening or closing with chains.

2.1 BASIC FUNCTIONS

The automatic stop system enables quick and reliable stop of the motor in close and open positions.
In case of power cut  you can release the operator by pulling the red knob and open the gate manually using the chain.

Important: 

Check routinely the torsion spring adjustment: when  the springs are not adjusted properly, the release  can cause 

spontaneous closing of the door. 

In an emergency case the door can be controlled manually through the chain.

Important: 

Use the manual chain without the release only at emergency, otherwise the chain reducer can fail.

Double end switches enable safe and reliable operation of the operator.

GENERAL INFORMATION

2.2 SPECIFICATIONS

Shaft-120

Power supply

~ 380V 50 Hz

Torque

120 Nm

Motor speed

1400 rpm

Shaft hole

25,4 mm with key way

Manual chain length

12 m

Shaft speed

22 rpm

Weight with chain

20 kg

Dimensions

430x290x120

Thermal protection

100 

0

C

Intensity

60%

Oil amount

0,25 l

Engine power

370 W

Protection rating

IP44

Operation temperature

-40 

0

C… +45 

0

C

Name

Quantity

1

Operator

1

2

Bracket

1

3

Set of fastenings

1

4

Manual operator chain (12m)

1

5

External button switch

1

6

Manual

1

3. Delivery set

After receiving the operator, unpack it and make sure, that the operator is not damaged. If any damages are found, please contact 

the supplier of the operator.

A standard package includes:

Содержание SHAFT-120

Страница 1: ...Installation and operating manual SHAFT 120 ...

Страница 2: ... components 8 7 Installation 9 7 1 On shaft mounting 9 7 2 Mounting via chain drive 10 8 Wiring 11 8 1 Control unit connection 12 9 Programming of operator 13 9 1 Selection of operational logic 13 10 Adjustment of close and open positions 13 10 1 Close position red cam 13 10 2 Open position blue cam 14 11 Release operation 16 12 Maintenance 17 13 Trouble shooting 18 14 Guaranty card 19 TABLE OF CO...

Страница 3: ...n release the operator by pulling the red knob and open the gate manually using the chain Important Check routinely the torsion spring adjustment when the springs are not adjusted properly the release can cause spontaneous closing of the door In an emergency case the door can be controlled manually through the chain Important Use the manual chain without the release only at emergency otherwise the...

Страница 4: ... gate Never let children play with the automatic system Deenergize the operator before putting it into operation after releasing or before removal its housing Do not go or drive through the gate during its closing or opening Do not impede moving of the gate Control of the gate shall be executed only under condition of its safe moving Do not pull the chain by hand to open or close the gate Ground p...

Страница 5: ...unting Mount the mounting bracket on the wall using screws The mounting bracket can be placed from the left or from the right of the operator Turn the release knob by 180 degrees counterclockwise Mount the first closing ring on the gate shaft Mount the operator on the gate shaft be sure that the bushing key is in its proper position and screw it to the mounting basis Mount the second closing ring ...

Страница 6: ...pply voltage terminal block X7 To select voltage 220V connect CO and 400V 2 Connection of supply voltage terminal block X5 Connect voltage 220V to terminals L1 L3 Connect voltage 380V to terminals L1 L2 L3 3 Motor terminal block X4 Connect motor to terminals U V and W 380V motor max operating current 9A wattage 4 kW 220V motor max operating current 2 4A wattage 2 4 kW 4 End switches terminal block...

Страница 7: ... not used install the jumper STOP and GND 220V Jumper for selection of supply voltage 380V Jumper for selection of supply voltage Fuse Transformer Jumpers Opening button Closing button External radio receiver Key switch 3 position control station Photocells Stop button Important If there are no safety devices install the jumper IR GND End switches Motor Black Brown Blue Supply voltage 3x380V 50 Hz...

Страница 8: ...lose and open the gate make sure that the blue cams push the micro switch and the indicator DL2 on the control unit is out Fine adjustment Turning the fine adjustment screw correct the closed position of the gate Clockwise turning of the screw causes earlier actuation of the end switch counter clockwise turning of the screw causes later actuation of the end switch Open and close the gate make sure...

Страница 9: ...only in case of emergency otherwise the reducer parts can be damaged 12 MAINTENANCE Make sure that the gate operate properly and are balanced Check operable condition of the system units and safety devices not less than once in six months Have qualified technicians to service the operator Keep the operator clean The manufacturing company reserves the right to make changes in the products desribed ...

Страница 10: ...n The door is not balanced Adjust the door Operator stops suddenly The operator s thermal protection works Let the operator cool Gate does not open completely or does not close completely Wrong adjustment of end switches Adjust end switches TROUBLE SHOOTING Bar code Component part Component part Component part Component part Component part Component part Component part Component part Serial number...

Страница 11: ...11 OPERATOR SHAFT 120 INSTALLATION AND OPERATING MANUAL notes ...

Страница 12: ... If you need any further information about purchasing distribution and maintenance contact our regional agents or our central office at the following address 120 Novaya street Akulovo village Odintsovo district Moskow region 143002 Russia Tel 7 495 933 2400 981 1133 E mail Info doorhan ru www doorhan ru ...