COMPONENTS

6. Operator components

Release cord

1. 

Manual chain

2. 

Reducer housing

3. 

End switches

4. 

Motor

5. 

Control unit

6. 

Manual drive unit

7. 

7. Installation

Before installation make sure that the gate is in good working condition and the torsion springs balance its leaf. Install the operator as 

described below (Section “On-shaft mounting” or “Mounting via chain drive”).

7.1 On-shaft mounting

Mount  the  mounting  bracket  on  the  wall  using  screws.  The  mounting  bracket  can  be  placed  from  the  left  or  from  the  right  of  the 

operator.

Turn the release knob by 180 degrees counterclockwise.
Mount the first closing ring on the gate shaft.
Mount the operator on the gate shaft (be sure, that the bushing key is in its proper position) and screw it to the mounting basis.
Mount the second closing ring on the gate shaft and push it close to the operator.
Mount the first closing ring close to the operator and fix both closing rings. 

Closing ring

Bushing key Electric operator

Closing ring

Bolt (M10)

Fastening bolt

Fastening bracket

Shaft

Содержание SHAFT-120

Страница 1: ...Installation and operating manual SHAFT 120 ...

Страница 2: ... components 8 7 Installation 9 7 1 On shaft mounting 9 7 2 Mounting via chain drive 10 8 Wiring 11 8 1 Control unit connection 12 9 Programming of operator 13 9 1 Selection of operational logic 13 10 Adjustment of close and open positions 13 10 1 Close position red cam 13 10 2 Open position blue cam 14 11 Release operation 16 12 Maintenance 17 13 Trouble shooting 18 14 Guaranty card 19 TABLE OF CO...

Страница 3: ...n release the operator by pulling the red knob and open the gate manually using the chain Important Check routinely the torsion spring adjustment when the springs are not adjusted properly the release can cause spontaneous closing of the door In an emergency case the door can be controlled manually through the chain Important Use the manual chain without the release only at emergency otherwise the...

Страница 4: ... gate Never let children play with the automatic system Deenergize the operator before putting it into operation after releasing or before removal its housing Do not go or drive through the gate during its closing or opening Do not impede moving of the gate Control of the gate shall be executed only under condition of its safe moving Do not pull the chain by hand to open or close the gate Ground p...

Страница 5: ...unting Mount the mounting bracket on the wall using screws The mounting bracket can be placed from the left or from the right of the operator Turn the release knob by 180 degrees counterclockwise Mount the first closing ring on the gate shaft Mount the operator on the gate shaft be sure that the bushing key is in its proper position and screw it to the mounting basis Mount the second closing ring ...

Страница 6: ...pply voltage terminal block X7 To select voltage 220V connect CO and 400V 2 Connection of supply voltage terminal block X5 Connect voltage 220V to terminals L1 L3 Connect voltage 380V to terminals L1 L2 L3 3 Motor terminal block X4 Connect motor to terminals U V and W 380V motor max operating current 9A wattage 4 kW 220V motor max operating current 2 4A wattage 2 4 kW 4 End switches terminal block...

Страница 7: ... not used install the jumper STOP and GND 220V Jumper for selection of supply voltage 380V Jumper for selection of supply voltage Fuse Transformer Jumpers Opening button Closing button External radio receiver Key switch 3 position control station Photocells Stop button Important If there are no safety devices install the jumper IR GND End switches Motor Black Brown Blue Supply voltage 3x380V 50 Hz...

Страница 8: ...lose and open the gate make sure that the blue cams push the micro switch and the indicator DL2 on the control unit is out Fine adjustment Turning the fine adjustment screw correct the closed position of the gate Clockwise turning of the screw causes earlier actuation of the end switch counter clockwise turning of the screw causes later actuation of the end switch Open and close the gate make sure...

Страница 9: ...only in case of emergency otherwise the reducer parts can be damaged 12 MAINTENANCE Make sure that the gate operate properly and are balanced Check operable condition of the system units and safety devices not less than once in six months Have qualified technicians to service the operator Keep the operator clean The manufacturing company reserves the right to make changes in the products desribed ...

Страница 10: ...n The door is not balanced Adjust the door Operator stops suddenly The operator s thermal protection works Let the operator cool Gate does not open completely or does not close completely Wrong adjustment of end switches Adjust end switches TROUBLE SHOOTING Bar code Component part Component part Component part Component part Component part Component part Component part Component part Serial number...

Страница 11: ...11 OPERATOR SHAFT 120 INSTALLATION AND OPERATING MANUAL notes ...

Страница 12: ... If you need any further information about purchasing distribution and maintenance contact our regional agents or our central office at the following address 120 Novaya street Akulovo village Odintsovo district Moskow region 143002 Russia Tel 7 495 933 2400 981 1133 E mail Info doorhan ru www doorhan ru ...

Отзывы: