background image

eLeCtRICAL InteRFACeS

7

1.1. Wiring diagram of control unit

WARNING! 

Switch off the power before operating with control board. Always install power cables apart from signal

ones. Use a braided shield cable to reduce induces noise. The wires in the cable shall be protected from contact with
any rough and sharp details.

1. ELECTRICAL INTERFACES

1.2. Description of elements of control unit

Elements of control unit

Contacts of control unit

Elements                                                                                                  

Description

TR1

Transformer

J0

Quick connector for receiver

DIP

Group of DIP-switches

FUSE

High-voltage fuse

FUSE2

Low-voltage fuse

TIMER W

Adjustment of reverse time after limit switch response

AUTO CL

Time delay before automatic closing

FORCE

Adjustment of traction force

Pins                                                                                                     

Description

~220 (N, L, PE)

Supply voltage

Motor (N, L1, L2)

Pin to connect motor

Lamp

Pin to connect warning light (see diagram)

Negative terminal for accessories power supply (24 V), 600 mA

+24 V

Positive terminal for accessories power supply (24 V), 600 mA

Sw Op

Output contact of limit switch to open

Sw Cl

Output contact of limit switch to close

EMRG

Contact pair for emergency stop (NC)

Ph Op

Output contact for photocells to open (NC)

Ph Cl

Output contact for photocells to close (NC)

Ped

Command to close (DIP2 is on) (NO)

Start

Command to open or step-by-step control (NO)

N

com

DCP(+)

com

com

com

r

GND

com

DC.P

com

com

com

LED3

GND

VCC  (+

24

)

CON

2

LED

2

GND

VCC  (+

24

)

CON

1

LED

1

IR

COM

NO              NC

com

DC.P

com

com

com

LED3

GND

VC

(+2

4)

CON2

LED2

GND

VC

(+2

4)

CON1

LED1

IR

CO

M

NO              NC

Timer W

Auto CL

Force

Fuse 2

Fuse

DIP

J1

J2

J3

J4

J0

 Connecting photocells to close. Set the jumper to NC when using photocells PhotoCell 

(DoorHan)

Connecting photocells to open. Set the jumper to NC when using photocells PhotoCell 

(DoorHan)

Receiver

 Jumpers

Capacitor

Red

Black

Green

Blue

Red

Limit switches

LED

 Observe the polarity

External control button

3

Содержание PCB-SL

Страница 1: ...DoorHan 2016 Programming instructions board PCB SL Actual versions pcb v 1 0 soft v 1 0 Content ReMote ContRoLLeR PRoGRAMMInG 2 3 CONTROL BOARD PCB SL...

Страница 2: ...erminals of control unit 4 1 4 DIP switches adjustment 5 1 5 Description of mechanically operated controls 5 2 REMOTE CONTROLLER PROGRAMMING 6 2 1 Cleaning of the receiver s memory 6 2 2 Record of Doo...

Страница 3: ...nect warning light see diagram Negative terminal for accessories power supply 24 V 600 mA 24 V Positive terminal for accessories power supply 24 V 600 mA Sw Op Output contact of limit switch to open S...

Страница 4: ...To connect some devices it s necessary to connect normally open NO contacts of these devices in parallel Ped command Pedestrian pedestrian crossing NO DIP2 off Ped command results in the door opening...

Страница 5: ...to install the jumper between EMRG contact terminals see wiring diagram 7 24 V DC output terminals of power supply transformer with 24 DC max load of 600 mA 1 4 DIP switches adjustment WARNING When ch...

Страница 6: ...s in the receiver s memory 60 pcs 2 3 Remote programming for Doorhan remote controllers Perform the items 1 4 within 5 second interval 1 Press and hold down the button 2 see figure of programmed remot...

Страница 7: ......

Страница 8: ...our company and believe that you will be satisfied with its quality For information on purchasing distribution and servicing contact DoorHan central office at Kralovsky VRCH 2018 Kadan 43201 Czech Rep...

Отзывы: