SAFETY RULES

3. SAFETY RULES 

3.1. SAFETY RULES WHEN WORKING AT HEIGHT

Work at height is work in any place located at height of 
1,3 m from the ground level and carried out from ladders, 
scaffolds, platforms and other devices. The state of health 
of the personnel working at height shall meet the medical 
requirements established for these works.
When working at height always use a safety belt. If it’s 
impossible to secure the belt to a building structure than 
use a safety rope instead. In such a case two installers 
should carry out all the works. Never use safety belts with 

metal chain slings while working around energized wiring 
and equipment!
Tools and fittings should be properly secured to prevent 
their falling while working above energized electrical in-
stallations. To pass tools and fittings upwards an installer 
standing on the ground should hold a rope with tied in-
struments to prevent its swinging and approaching to en-
ergized electrical installations.

3.2. SAFETY RULES WHEN WORKING FROM LADDERS AND STEPLADDERS

Straight ladders and stepladders should be properly se-
cured to prevent their lateral movement and overturn. Sta-
bilize the base of the ladder using sharp-tipped feet for 

the ground surface and anti-slip safety shoes for smooth 
surfaces like metal, tile or concrete.

IT IS PROHIBITED TO:

 

ƒ

work from the rung located less than one meter from the ladder top;

 

ƒ

use power tools when working from a ladder;

 

ƒ

work from the two top rungs of a stepladder which has no safety hand rails or ladder stop;

 

ƒ

be on the steps of a ladders or stepladder for more than one person;

 

ƒ

stand under the ladder which is used for work;

 

ƒ

leave tools or materials on top of any ladder.

3.3. SAFETY RULES WHEN OPERATING POWER TOOLS

Only qualified and specially trained personnel acquainted 
with electrical safety instructions can operate power tools. 
It is recommended to use power tools operating at volt-
age not exceeding 380/220 V. Choose power tool taking 
into consideration electric shock hazard of the premise. 
Ground metal housing of electric tool operating at voltages 
above 42 V AC and above 110 V DC when working in haz-
ardous areas and outdoor installations. Tool connection 
plug should have a ground contact. Plug power tools only 
in the grounded power supply network. When using exten-
sion cords make sure they have grounded plugs and sock-
ets. Always wear protective rubber gloves or rubber bot-
tom shoes or sneakers when using electric instruments. 
Protective devices must be tested in accordance with the 
procedure established by law.
Prior to operation:

 

ƒ

ensure all the components are in place and properly 
secured;

 

ƒ

check for worn out cable (wire), its protective tube and 
plug; damaged insulating parts of the housing, handle 
and brush holder covers; absent or damaged protective 
casings;

 

ƒ

make sure ground circuit between the housing and the 
ground contact of the plug is whole;

 

ƒ

ensure the main switch works properly;

 

ƒ

check operation of power tools at idle.

Use only properly functioning, checked and sealed tools. 
Never bend or twist electric cables or position any trailing 
wires where different structures and materials are stored 
or vehicles move. When working in rainy weather (snow-
fall) protect with canopies the area where cables are laid 
or power tools are used.

IT IS PROHIBITED TO:

 

ƒ

hold the instrument by its cord;

 

ƒ

remove chips or sawdust from the cutting tool and replace the cutting tool until it stops completely. Use corre-
sponding instruments to fasten the replaceable tool;

 

ƒ

plug the power tool in a circuit with characteristics which do not correspond to the specified in data sheet;

 

ƒ

move an electric tool with operating motor from one working place to another;

 

ƒ

leave unattended a plugged-in or operating electric instrument;

 

ƒ

leave electric instrument unattended to prevent its unauthorized use.

Содержание DSHINF Series

Страница 1: ...1 DoorHan 08 2020 Operation and Installation Instructions Inflatable dock shelter of DSHINF series General Information 2 Design 2 Safety Rules 3 Installation 4 Operation 20 Appendix 21...

Страница 2: ...ght 3 Front storage curtain 4 Left right frame 5 Counterweight 6 Blower 7 Dock shelter roof 2 DESIGN Table 1 Specifications Parameter Value Air bags control system Three phase power supply 380 415 V 5...

Страница 3: ...ety instructions can operate power tools It is recommended to use power tools operating at volt age not exceeding 380 220 V Choose power tool taking into consideration electric shock hazard of the pre...

Страница 4: ...el trained at DoorHan training center and having a corresponding certificate Use of appropriate mounting tools is strictly required The manufacturer does not di rectly control installation operation a...

Страница 5: ...4 Fig 5 Fig 6 Fig 7 Fig 10 Fig 8 Fig 11 Fig 9 Fig 12 4 3 PACKAGE INVENTORY INSTALLATION 2 pcs 2 pcs 2 pcs Fig 14 Fig 15 Fig 13 Fig 18 Fig 17 Fig 16 Fig 19 B C E D F L 250 mm 110 mm 6 3 25 mm 6 3 38 m...

Страница 6: ...6 INSTALLATION Fig 1 2 Fig 1 3 Fig 1 Prepare side frames View 1 100 mm 500 mm Fig 1 1 View 1 125 mm 7 mm 50 mm 4 4 INSTALLATION...

Страница 7: ...7 INSTALLATION Fig 2 View 2 Fig 2 1 View 2 105 mm Fig 2 2...

Страница 8: ...8 Fig 3 Fasten side frames to building wall Fig 3 1 View 1 Fig 3 2 View 2 200 mm View 1 View 2 INSTALLATION...

Страница 9: ...9 INSTALLATION Fig 4 3 View 2 Fig 4 1 View 1 Fig 4 Fig 4 4 Fig 4 2 100 mm 300 mm View 1 View 2...

Страница 10: ...10 INSTALLATION Fig 5 Fig 5 2 Fig 5 3 Fig 5 1...

Страница 11: ...11 INSTALLATION Fig 6 Install top air bag Fig 6 1 Fig 6 2...

Страница 12: ...12 Fig 7 Install guide rod Fig 7 1 Fig 7 2 Fig 7 3 INSTALLATION...

Страница 13: ...13 INSTALLATION Fig 8 Fig 9 Fig 10 400 mm 155 mm 90 820 mm...

Страница 14: ...Install counterweight Fig 13 1 View 1 Fig 13 2 View 2 View 2 View 1 B INSTALLATION Fig 12 Fig 11 F Before attaching the counterweight cable to the shaft turn the shaft until the top air bag rises all...

Страница 15: ...15 INSTALLATION Fig 14 Connect air transfer tubes Fig 14 1 Fig 14 2 B...

Страница 16: ...16 INSTALLATION Fig 15 Fig 15 1 Fig 15 2 Fig 15 4 Fig 15 3 Fig 15 5 E D D D...

Страница 17: ...17 Fig 16 Fig 16 1 Fig 16 2 INSTALLATION B B...

Страница 18: ...18 Fig 17 Fig 17 1 Fig 17 2 INSTALLATION B B...

Страница 19: ...19 Fig 18 Fig 20 Fig 19 Fig 21 INSTALLATION 4 2 u 32 mm C...

Страница 20: ...ck is stationary the handbrake is put on the wheels are choked 4 Inflate dock shelter switch the blower on by pressing a push button on the control unit if the blower motor is operated with the dock l...

Страница 21: ...100 30 100 10 10 1 0 10 Dock shelter wall Dock leveler Bumper Dock shelter wall Dock leveler Bumper A A A A Bar C Clamping plate Bumper PVC buffer Dock shelter wall Rubber bumper PVC buffer Rubber bu...

Страница 22: ...22 Fig 2 Inflatable dock shelter exploded view APPENDIX 1 2 6 9 8 10 16 19 18 3 5 4 7 15 17 20 13 20 11 12 21 14 22...

Страница 23: ...10 DKHA20040 3410 Clamping profile L 3410 mm 11 DSI02 101 Counterbalance cover 2000 mm 12 DSI02 1101 Mounting angle 13 168 Rivet 4 0 u 12 14 14019 Self tapping screw ISO 15480 ST 6 3 u 25 15 9502 Sel...

Страница 24: ...KHA20040 3610 Top clamping profile L 3610 mm 11 DSI02 101 Counterbalance cover 2000 mm 12 DSI02 1101 Mounting angle 13 168 Rivet 4 0 u 12 14 14019 Self tapping screw ISO 15480 ST 6 3 u 25 15 9502 Self...

Страница 25: ...KHA20040 3610 Top clamping profile L 3610 mm 11 DSI02 101 Counterbalance cover 2000 mm 12 DSI02 1101 Mounting angle 13 168 Rivet 4 0 u 12 14 14019 Self tapping screw ISO 15480 ST 6 3 u 25 15 9502 Self...

Страница 26: ...ly 4870 u 800 mm 1 DSI07 32 Left side air bag 4600 u 800 mm left 1 2 DSI03 11 Left shelter wall assembly 4870 u 800 mm 1 Table 2 to Fig 3 Right side frame Part number Description Qty DSI04 2 Right fra...

Страница 27: ...15 Right end support bracket 70u 5 without plate 1 6 14019 Self tapping screw ISO 15480 ST6 3 u 25 4 Table 2 to Fig 4 Top frame with 1600 mm top air bag option Part number Description Qty DSI01 4 Uppe...

Страница 28: ...l formed channel 60 32 4 mm shelter side wall with a fastening angle self tapping screw PVC dowel shelter side wall with a fastening angle concrete brick Installation clearance 600 700 mm for a shelte...

Страница 29: ...U V W PE M 2 4 6 PE L2 L3 L1 N 3 5 1 13 Fig 6 Blower motor wiring diagram If the blower motor is connected to the dock leveler control unit than see a corresponding wiring diagram in the control unit...

Страница 30: ...30 NOTES...

Страница 31: ...NOTES 31...

Страница 32: ...n on purchasing distribution and servicing contact DoorHan central office at 120 Novaya street bld 1 Akulovo village Odintsovo district Moscow region 143002 Russia Phone 7 495 933 24 00 E mail info do...

Отзывы: