ENGLISH
13
Port
Description
LAN/POE
The device does not have an integrated standarized RJ45 socket to ensure ...
• that the device rests as flat as possible on the wall.
• that no wall needs to be levered up.
• that a strong and inflexible Cat.6 or Cat.7 installation cable can be used.
Use only four wires (1, 2, 3 and 6) of a standard Network cable Cat.5 or better,
coming from the Internet Router/PoE-Switch/PoE-Injector.
Cat.5 / Cat.6 Network cable
T+ White and orange network cable wire (Number 1, Transmit Data +)
T - Orange network cable wire (Number 2, Transmit Data -)
R+ White and green network cable wire (Number 3, Receive Data +)
R - Green network cable wire (Number 6, Receive Data -)
Cat.7 Network cable (Installation cable)
T+ White network cable wire from pair “orange/white” (Number 1, Transmit Data +)
T-
Orange network cable wire from pair “orange/white” (Number 2, Transmit Data -)
R+ White network cable wire from pair “green/white” (Number 3, Receive Data +)
R- Green network cable wire from pair “green/white” (Number 6, Receive Data -)
NOTICE
Do not power the device simultaneously via the power supply from the
power supply unit (mains adaptor) and the power supply via PoE.
R1, R1
Bi-stable latching relay #1, max. 24 V DC/AC, 1 A. Security feature: The relay
keeps its state even in the case of loss of power. You can configure the default
state of the relay (open/close) via the DoorBird App. These ports can be used
to connect e.g. an electric door opener. The device does not supply power to
the connected device. The power supply for the electric door opener must be
installed separately.
When wiring an electric door opener directly to a door station, there is a
risk that the electric door opener could be tampered by unauthorized
third parties (e. g. by breaking the door station and short-circuiting the
wiring of the door opener). Therefore, we generally recommend the use of
a remote safety relay mounted indoors (e. g. DoorBird I/O Door Controller
A1081) for wiring an electric door opener for a more secure installation in
your home.
E1, E1
Digital input (0 V, 0 A (NO)), for door opener button, max. 0 V DC/AC, 0 A.
These ports can be used to connect e.g. a door opener button inside the home. It
will can trigger the bi-stable latching relay of the device (R1, R1)
NOTICE
Please make sure to add no voltage on these ports. Extra voltage may
destroy the device immediately.
15 VDC -
15 V DC Power supply input, negative pole (-). Please connect the black wire of
the power supply unit (mains adaptor) supplied with this device if you do not
power the device using PoE.
NOTICE
Do not power the device simultaneously via the power supply from the
power supply unit (mains adaptor) and the power supply via PoE.
15 VDC +
15 V DC Power supply input, positive pole (+). Please connect the red wire of the
power supply unit (mains adaptor) supplied with the device here, if you do not
power the device using PoE.
NOTICE
Do not power the device simultaneously via the power supply from the
power supply unit (mains adaptor) and the power supply via PoE.
R1
R1