background image

Warranty

Head Office & Factory : 332 Hwagok-ro, Jangan-myeon,

   Hwaseong-si, Gyeonggi-do, Korea

TEL : +82-31-831-1200  FAX : +82-31-831-1240
Hompage : www.doochpump.com

This product has been manufactured through a strict quality management and inspection
process by Dooch Technical Team. The warranty period is 12 months from the date
manufactured, provided that, the warranty period is subject change depending on the terms
and condition of the agreement under separate cover.

Maker

Name

Address

Tel.

Name

Address

Tel.

Installation Date

DOOCH CO., LTD.

Model No.

Warranty Period

Customer

Information

Sales Office

(Distributor)

FOC Service
If there is any failure in the product during the afore-mentioned warranty period you can have
it repaired FOC by requesting our distributor or designated service center subject that you are
found to have used it under our recommended environment. For further details, please refer
to out company's regulation.
Charged Service

 

In the event of any of the following cases, the service will be charged.

- The failure occurred from the consumer's improper storage, handling, and careless handling
- The failure occurred from the consumer's error in the design of software or hardward
- The failure occurred from the error of power source and the defect of the connector
- The failure occurred from the force majeure (fire, flood, gas disaster, earthquake, etc.)
- The product was modified or repaired at the discretion of the consumer in the place other
  than our distributor or the Service Center.
- The name plate provided by DOOCH is not attached on the product
- The product was used in an improper way or beyond the operating range.

 

Waiver of the warranty for the mechanical loss, etc.

Dooch Co., Ltd. doesn't bear any responsibility to indemnify indirect, special, incidental, or
consequential loss (including the indemnification of sales loss, loss profit, etc.

Содержание NSQ Series

Страница 1: ...NSQP HNSQP BOOSTER PUMP SYSTEM PREMIUM...

Страница 2: ......

Страница 3: ...Product Components of Product Method of Operation Installation Inspection and Maintenance Drive Control mode Method of pressure setting Parameter Mode Pr Pump dr Drive Fault History Table Measures be...

Страница 4: ...e manifold H NSQ 3 DRL 10 6 80A NSQ Drive Exclusive Inverter for Pump Power Range 0 75 22kW Input Power 1 200 230V 0 75 2 2kW 3 380 440V 0 75 22kW Output Power 3 380V Frequency 50 60Hz Model Feature S...

Страница 5: ...d In addition you are required to have this User s Manual properly delivered to the end user and maintenance manager Safety Precautions Remark To prevent injury and property damage follow these instru...

Страница 6: ...shock Do not use the cable when its insulating tube is damaged Otherwise you may get an electric shock Do not subject the cables to scratches excessive stress heavy loads or pinching Otherwise you ma...

Страница 7: ...he power is off when installing the VFD To prevent the risk of fire or electric shock keep the connected wire in a sound condition Use the wire that meets the standard in a recommended length B Wiring...

Страница 8: ...ffer from analogye value Save all of run history of pump Save all of the trip and error history of pump all pumps have evenly run time The pump operate individually Input muti functional external anal...

Страница 9: ...on Manifold Discharge Pressure Transmitter Suction Isolating Valve Check Valve Pressure Tank No 2 1 3 4 5 6 7 8 9 10 Discription 1 2 6 2 6 2 6 1 1 1 1 1 PUMP 1 PUMP 1 Quantity 4 20mA Standard Manifold...

Страница 10: ...r Suction Isolating Valve Check Valve Air Vent No 2 1 3 4 5 6 7 8 9 10 Description 1 2 6 2 6 2 6 1 1 1 1 1 Pump 1 Pump 1 Quantity 4 20mA In Line Manifold Pressure Tank 11 1 Depend on pump size Comment...

Страница 11: ...e mater pump 3Pump system Pressure Starting Pressure Quantity q0 q1 Stop pressure of master pump q2 q3 Step Operating Mode All pumps operate consistantly by a method of step operating protects the pum...

Страница 12: ...demand of high water consumption or a location where the pump needs to maintain contstant pressure If Pr 54 lead pump alternation time is set at 0 the first pump will operate as lead pump The lead pum...

Страница 13: ...on please install within a facility that is equipped with drainage The pump installation shall not allow the system pipeline tensile force to be transferred to the suction and discharge pipe Suction p...

Страница 14: ...s five digits of 7 segment four LED lamps to display various settings and states and consists of four buttons to operate drive or enter setting FND Drive LAMP FND BUTTONS Instructions on setting the p...

Страница 15: ...Drive Group Button Part Button part consists of four buttons and it is used for parameter setting or movement Drive Operation Turned on for waiting and flickered on operation Turned on during stop Tu...

Страница 16: ...splay Current output current display Set Pressure User s Set pressure display Output Current Current DC Link display Pressing the will display the current P S H o U A in sequence Press the to change t...

Страница 17: ...92 Low Level Trip Time of Pressure Sensor S W Version 1 0 25 0 bar 1 0 1 0 bar 0 1 0 2 0 bar 0 200 sec 0 6 0 2 0 24 hour 1 100 sec 0 Sen1 Cap bar 0 10 0 bar 0 100 sec 0 200 sec 0 250 sec 0 1 0 bar 0...

Страница 18: ...onds and maintained as stopped status between 11 59 seconds based on 1 minute This function is to prevent the pump from freeze and burst by generating frictional heat upon rotation within pump casing...

Страница 19: ...ional Description Setup Data 0 factory setting Not use 485 comm 1 Use 485 comm Functional Description Setup Data 1 250 Factory Setting 1 f the number of data request protocol is different data is not...

Страница 20: ...and the one with less power consumption is to be started alternatively at the same time in order to prevent a specific drive pump being operated constantly If times is set drives are forcedly shifted...

Страница 21: ...issue the low pressure alarm Pr 72 High Pressure Alarm Time It sets maintaining time of high pressure alarm level to issue the high pressure alarm That is if the current pressure increases above the...

Страница 22: ...Level Alarm Pressure Level It is a pressure level to determine low water level when selecting software detection method from Low Water Level Alarm Detection Method Selection Pr 76 Pr 73 Low Pressure...

Страница 23: ...Restart after Trip Accumulated Mega Wh indication Accumulated Kilo Wh indication Initializing Integrated Watt Initalization Code Description Display dr 12 dr 20 dr 22 dr 23 dr 37 dr 38 dr 53 dr 54 dr...

Страница 24: ...sure to check it dr 01 Command Input Location Setup It sets operation command location When selecting FND key it is possible to issue operation command using key on main body of drive When setting up...

Страница 25: ...the trip occurs more than specified number it can not restart If there is no trip during certain time No of trip might be deleted It may not be restarted according to error code Refer to Chapter 7 Fau...

Страница 26: ...s re setted to the factory setting Setup Data Functional Description 0 Factory Setting To maintain content 1 To initialize dr 53 dr 54 to the factory settings Setup Data Functional Description 0 Facto...

Страница 27: ...Temp Storage Temp Surrounding Humidity 380 440 0 05 50 60 3 380V 440V 50 60 IP55 1 15 V F Control Slip Compensation Control 1 of Rated Frequency 120 1 Min Manual Torque Boost 0 10 FND Terminal Commun...

Страница 28: ...nsor Error High Pressure Alarm Low Pressure Alarm Low Level Alarm Drive Arm Short Trip Drive H W Over Current Trip Drive H W Over Current Restriction Trip Drive Overheat Trip DC Link Low Voltage Trip...

Страница 29: ...op after elapsed High Pressure Alarm Time Pr 72 and the alarm lamp will be turned on It may occur on temporary installation site or trial run test Reaction Check the setup pressure and high pressure a...

Страница 30: ...he water In case of not using the low water level sensor the software generates the alarm when the current pressure is maintained under the low pressure alarm level Pr 75 and operation continues for l...

Страница 31: ...n Add Hi Add Lo Data Hi Data Lo CRC END Query Example of writing the set pressure 5 5bar Single Write 3 5 byte Time X X 0 6 2 0 0 2 0 0 3 7 X X X X 3 5 byte Time Hex Start Slave ID Function Add Hi Add...

Страница 32: ...40 485 comm Mode RS485 comm speed Pr 42 485 comm Speed RS485 comm ID Pr 41 485 comm ID CAN comm ID Pr 51 CAN comm ID must be set as 485 is communication with master of pump system Verify the starting...

Страница 33: ...sed it under our recommended environment For further details please refer to out company s regulation Charged Service In the event of any of the following cases the service will be charged The failure...

Страница 34: ...NSQP 1507 M NSQP HNSQP BOOSTER PUMP SYSTEM PREMIUM DOOCH CO LTD 332 Hwagok ro Jangan myeon Hwaseong si Gyeonggi do Korea TEL 82 31 831 1200 FAX 82 31 831 1240 www doochpump com www...

Отзывы: