![DONGBU DAEWOO ELECTRONICS DWC-PS1512X Скачать руководство пользователя страница 59](http://html.mh-extra.com/html/dongbu-daewoo-electronics/dwc-ps1512x/dwc-ps1512x_service-manual_2520840059.webp)
57
✦
SWITCH THERMOSTAT(BIMETAL)
function : control the duct temperature, if the temp reached over 150°C, all power supply will be cut. and if the temp go
down 120°C the power will be ON.
protecting overheating by cutting off heater power supply if the temperature rises over 150°C, and reoperating
heater by connecting heater power supply if the temperature falls under 120°C.
• OPERATING TEMPERATURE
• PICTURE
✦
UNIT FAN MOTOR
function : circulating the inside air during dry process.
• SPEC
• PICTURE
• FAILURE MODE : * E3 shown : FAN MOTOR cannot work.
• CHECKING METHOD : Check the FAN MOTOR is short, and replace with new one.
ITEMS
SPEC
RATING VOLTAGE
24V
RPM
MOTOR
3700 ± 10%
DUCT FAN AS
1900 ± 10%
ROTAING DIRECTION
CW
OPEN TEMPERATURE(OFF)
150°C ± 5°C
CLOSE TEMPERATURE(ON)
120°C ± 5°C
WFC3V11ZDNH01D2GW(DWC-PS1512X)_칠레향(SM).indd 57
2017-10-26 오후 4:17:41
Содержание DWC-PS1512X
Страница 10: ...8 2 INLET BOX AS WFC3V11ZDNH01D2GW DWC PS1512X _칠레향 SM indd 8 2017 10 26 오후 4 17 31 ...
Страница 12: ...10 3 CABINET F ASSY WFC3V11ZDNH01D2GW DWC PS1512X _칠레향 SM indd 10 2017 10 26 오후 4 17 32 ...
Страница 15: ...13 5 BASE U AS 1 2 3 5 4 WFC3V11ZDNH01D2GW DWC PS1512X _칠레향 SM indd 13 2017 10 26 오후 4 17 34 ...
Страница 69: ...67 6 WIRING DIAGRAM WFC3V11ZDNH01D2GW DWC PS1512X _칠레향 SM indd 67 2017 10 26 오후 4 17 43 ...