50
5. Error reporting function
5-1. IE (Input Error) - Error in water supply
1) Conditions of Occurrence
①
In case the designated water level is not reached in 5 minutes during water supply or re-supply
2) All LEDs are turned off and 'IE' blinks in18:88 display.
3) Error buzzer alarm is sounded for 10 seconds per every 10 minutes.
4) Error display is cleared when turning off/ on power.
5-2. OE (Output Error) - Error in drainage
1) Conditions of Occurrence
①
In case water level does not reach reset point in 10 minutes after drainage starts
2) All LEDs are turned off and 'OE' blinks in 18:88 display.
3) Error buzzer alarm is sounded for 10 seconds per every 10 minutes.
4) Error display is cleared when turning off/ on power.
5-3. UE (Unbalance Error)
1) Conditions of Occurrence
①
In case main spin-drying is not reached within 20 cycles of balance spin-drying
②
In case balance spin-drying fails during interim spin-drying, UE occurs as the cycle moves to the next
process.
2) All LEDs are turned off and 'UE' blinks in 18:88 display.
3) Error buzzer alarm is sounded for 10 seconds per every 10 minutes.
4) Error mode is cleared by opening door and organizing the laundry in spin-dry chamber, closing door and
pressing start/ temporary stop button. Then, spin-drying begins again.
WFC3V11ZDNH01D2GW(DWC-PS1512X)_칠레향(SM).indd 50
2017-10-26 오후 4:17:41
Содержание DWC-PS1512X
Страница 10: ...8 2 INLET BOX AS WFC3V11ZDNH01D2GW DWC PS1512X _칠레향 SM indd 8 2017 10 26 오후 4 17 31 ...
Страница 12: ...10 3 CABINET F ASSY WFC3V11ZDNH01D2GW DWC PS1512X _칠레향 SM indd 10 2017 10 26 오후 4 17 32 ...
Страница 15: ...13 5 BASE U AS 1 2 3 5 4 WFC3V11ZDNH01D2GW DWC PS1512X _칠레향 SM indd 13 2017 10 26 오후 4 17 34 ...
Страница 69: ...67 6 WIRING DIAGRAM WFC3V11ZDNH01D2GW DWC PS1512X _칠레향 SM indd 67 2017 10 26 오후 4 17 43 ...