56
742.641 | 11.43
EN
8.7
Initial commissioning of the inverter
8.7.1
Function
Conditions for starting initial commissioning
Initial commissioning starts automatically when at least the AC connector has been installed and
switched on as described previously.
If initial commissioning is not fully completed, then it starts again anew the next time the device is
switched on.
Guided initial commissioning
Initial commissioning is a guided process for setting the display language, date/time and country.
Setting the country
The following applies when setting the country:
• The country set must always be the same as the country where the inverter is installed. This
causes the inverter to load the legally prescribed permissible deviations for rated voltage and
frequency applicable to the selected country; more information on this is provided in
•
The country can only be set once!
Contact your installer if you have set the wrong country.
• Contact your installer if you cannot select the country where your inverter is installed.
Button functions during initial commissioning
The operating buttons have the following functions during initial commissioning:
But-
ton
Function (depending on the respective display contents)
ESC
press briefly
• shows the previous page
• discards any changes
press longer
(≥ 1 second)
jumps to the first initial commissioning page
press briefly
• moves the selection bar 1 position upwards; after the first entry, the bar
jumps to the last entry
• when performing numerical settings, moves the selection 1 position to
the left
• increases a setting value by 1 step; the highest possible value is fol-
lowed by the lowest possible value
press briefly
• moves the selection bar 1 position downwards; after the last entry, the
bar jumps to the first entry
• when performing numerical settings, moves the selection 1 position to
the right
• decreases a setting value by 1 step; the lowest possible value is followed
by the highest possible value
SET
press briefly
• a selected numerical value starts flashing and can be changed
• adopts a change
• changes the state of a control element (check box/radio button)
press longer
(≥ 1 second)
• shows the next page
• answers a query dialog with
Yes
Tab. 9: Functions of the operating buttons during initial commissioning