29
Donaldson Company, Inc.
Pleated Bag with Snap-In Design Filter
Removal
1. Properly shutdown the system and lock out electrical
system.
2. Access clean air plenum through door.
3. Grab snap band finger loop to remove the snap band
and discard. The replacment filter comes with a new
snap band.
4. Squeeze the flange of the molded top at the center
of the straight-a-ways of the oval. While doing so,
rock and lift to release the molded tops from the
tubesheet.
5. Lift the filter out of the tubesheet.
Pleated Bag with Snap-In Design Filter
Installation
1. Slowly lower the filter through the tubesheet hole.
Squeezing the filter to get the straps through the
tubesheet may be required.
2. Gently push the flexible urethane top of the filter on
one side until it snaps into the tubesheet hole.
Push the opposite side of the top of the filter until it is
securely snapped into the tubesheet hole.