c. Second stage filter element
The genuine filter element is the only replacement filter that will provide the
high level of performance that you expect from your investment in the WSO
Flex Mist collector.
Do not drop or rap the new filter element on the floor or any other hard surface.
Damage to the filter element will occur.
For easiest maintenance, the wrap and second stage filter element can be changed
at the same time. The second stage filter element is accessed through the door.
1. Pull the retention handle out and down to a horizontal position.
2. Slide the filter element out of the unit.
3. As the filter element is being removed, a plastic garbage bag can be slipped over
the top of the filter element.
The filter element may then be tipped as it is removed while the bag is being
closed over the bottom of the filter element.
4. Install the new filter element (with a new wrap) in the unit by placing the new
filter element on the platform with the gasket up. The platform can be flipped to
fit either the Synteq or Dryflo element.
5. Push it back in until the filter element stops.
6. Lift the retention lever up into the unit.
1
3
2
Figure 21: 2