Installation, Operation and Maintenance manual
33
WSO Flex
START-UP CHECK LIST
Follow all steps before first start-up and when the mist collector is not been
used for a long period.
For daily use follow steps 1, 2, 3, 4 and 6.
1. Check that the outlet of the fan is free of debris before starting.
Too much airflow can cause electrical failure of the fan motor or dramatically
reduce the life of the filter elements.
2. Be sure that the inlet ducting is properly installed and duct joints are sealed.
3. Make certain the filter element is properly installed.
4. Check if the access door is closed (markings on latch should be aligned).
5. If a collection bottle is used, make sure that the faucet is closed.
6. Connect the mist collector to the main power.
7. Adjust speed of the airflow to your convenience/dependency on application with
damper valve at the outlet panel. Check with your application engineer.